Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2663▼ 380 respecto a la semana anterior
Críticas / altas1289▼ 36 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)244▼ 274 respecto a la semana anterior
5 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (5.7) | 0.30% | — | Contechealth Cms8000 Firmware | 13/9/2022 | 17/6/2026 | The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or… | |
| Modificada | Media (4.4) | 0.19% | — | Contechealth Cms8000 Firmware | 13/9/2022 | 17/6/2026 | Multiple binary application files on the CMS8000 device are compiled with 'not stripped' and 'debug_info' compilation settings. These compiler settings greatly decrease the level of effort for a threat actor to reverse engineer sensitive code and identify additional vulnerabilities. | |
| Modificada | Alta (7.5) | 0.98% | — | Contechealth Cms8000 Firmware | 13/9/2022 | 17/6/2026 | The CMS800 device fails while attempting to parse malformed network data sent by a threat actor. A threat actor with network access can remotely issue a specially formatted UDP request that will cause the entire device to crash and require a physical reboot. A UDP broadcast request could be sent that causes a mass… | |
| Modificada | Media (6.1) | 0.32% | — | Contechealth Cms8000 Firmware | 13/9/2022 | 17/6/2026 | Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters | |
| Modificada | Media (6.8) | 0.39% | — | Contechealth Cms8000 Firmware | 13/9/2022 | 17/6/2026 | A threat actor with momentary access to the device can plug in a USB drive and perform a malicious firmware update, resulting in permanent changes to device functionality. No authentication or controls are in place to prevent a threat actor from maliciously modifying firmware and performing a drive-by attack to load… |