Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2557▼ 320 respecto a la semana anterior
Críticas / altas1342▲ 78 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 7 respecto a la semana anterior
Sin puntuar (sin CVSS)62▼ 466 respecto a la semana anterior
10 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.8) | 0.38% | — | Schneider-electric CitectscadaSchneider-electric Scada Expert Vijeo Citect | 31/5/2019 | 17/6/2026 | In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials. | |
| Modificada | Alta (7.8) | 1.8% | — | Schneider-electric CitectscadaSchneider-electric Powerlogic ScadaSchneider-electric Struxureware Powerscada ExpertSchneider-electric Struxureware Scada Expert Vijeo Citect | 26/2/2014 | 16/6/2026 | Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of… | |
| Modificada | Media (6.9) | 0.73% | — | Schneider-electric CitectscadaSchneider-electric Powerlogic ScadaSchneider-electric Vijeo Citect | 9/8/2013 | 16/6/2026 | Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity… | |
| Modificada | Alta (10) | 11% | — | Mitsubishi-automation Mitsubishi MX ComponentSchneider-electric CitectfacilitiesSchneider-electric Citectscada | 19/4/2013 | 16/6/2026 | Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control. | |
| Modificada | Media (4.6) | 0.47% | — | Mitsubishi-automation MX4 ScadaSchneider-electric Citectscada | 15/9/2012 | 16/6/2026 | Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence. | |
| Modificada | Media (5) | 1.7% | — | Schneider-electric Vijeo HistorianSchneider-electric CitecthistorianSchneider-electric Citectscada Reports | 2/12/2011 | 16/6/2026 | Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors. | |
| Modificada | Media (4.3) | 2.0% | — | Schneider-electric Vijeo HistorianSchneider-electric CitecthistorianSchneider-electric Citectscada Reports | 2/12/2011 | 16/6/2026 | Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |
| Modificada | Alta (9.3) | 13% | — | Schneider-electric Vijeo HistorianSchneider-electric CitecthistorianSchneider-electric Citectscada Reports | 2/12/2011 | 16/6/2026 | Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors. | |
| Modificada | Media (4.3) | 1.5% | — | Schneider-electric Vijeo HistorianSchneider-electric CitecthistorianSchneider-electric Citectscada Reports | 2/12/2011 | 16/6/2026 | Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors. | |
| Modificada | Alta (7.6) | 78% | — | CitectfacilitiesCitectscada | 16/6/2008 | 16/6/2026 | Stack-based buffer overflow in the ODBC server service in Citect CitectSCADA 6 and 7, and CitectFacilities 7, allows remote attackers to execute arbitrary code via a long string in the second application packet in a TCP session on port 20222. |