« Volver al listado

CVE-2011-4035

Estado: ModificadaMedia (4.3)—

Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (3)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2011-4035",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ]
  },
  "affected": [
    {
      "source": "cret@cert.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2011-12-02T11:55:05.450",
  "references": [
    {
      "url": "http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695",
      "source": "cret@cert.org"
    },
    {
      "url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page",
      "source": "cret@cert.org"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "cret@cert.org"
    },
    {
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71503",
      "source": "cret@cert.org"
    },
    {
      "url": "http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71503",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de ejecución de secuencias de comandos en sitios cruzados (XSS) en Schneider Electric Vijeo Historian v4.30 y anteriores, CitectHistorian v4.30 y anteriores, y CitectSCADAReports v4.10 y anteriores permite a atacantes remotos inyectar secuencias de comandos web o HTML a través de vectores no especificados."
    }
  ],
  "lastModified": "2026-06-16T23:34:19.390",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FA173AD2-52AF-4401-9A29-757B68168B4D",
              "versionEndIncluding": "4.30"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "00E3E11B-E433-4D89-9525-8159CEC30DC0"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2788D1E5-206A-4AC8-AA28-65E5EE268B59"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "99B88BED-7F2F-4F89-9BD1-B7EDC1608531"
            }
          ],
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "859A64AD-1FB2-4A7C-AE4D-26951FC050F9",
              "versionEndIncluding": "4.30"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B491E331-B533-4E09-966E-45A3BE724C5A"
            }
          ],
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "106C6198-C341-4B10-8788-A8FA51F137F1",
              "versionEndIncluding": "4.10"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "38765B0B-9C09-4BC0-9E50-D0C6E8969A77"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cret@cert.org"
}