CVE-2011-4033
Estado: ModificadaMedia (4.3)—
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.
CVSS
- Versión: 2.0
- Vector: AV:N/AC:M/Au:N/C:N/I:N/A:P
- Puntuación base: 4.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.55%
- Percentil entre todas las CVEs puntuadas: 74
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-119
Referencias
- http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695
- http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page
- http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf
- http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695
- http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page
- http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2011-4033",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"affected": [
{
"source": "cret@cert.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2011-12-02T11:55:05.090",
"references": [
{
"url": "http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695",
"source": "cret@cert.org"
},
{
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page",
"source": "cret@cert.org"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf",
"tags": [
"US Government Resource"
],
"source": "cret@cert.org"
},
{
"url": "http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf",
"tags": [
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors."
},
{
"lang": "es",
"value": "Desbordamiento de búfer en el control ActiveX TeeChart Steema, tal como se utiliza en Schneider Electric Vijeo Historian v4.30 y anteriores, CitectHistorian v4.30 y anteriores, y CitectSCADAReports v4.10 y anteriores, permite a atacantes remotos provocar una denegación de servicio a través de vectores no especificados."
}
],
"lastModified": "2026-06-16T23:34:19.183",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FA173AD2-52AF-4401-9A29-757B68168B4D",
"versionEndIncluding": "4.30"
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "00E3E11B-E433-4D89-9525-8159CEC30DC0"
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2788D1E5-206A-4AC8-AA28-65E5EE268B59"
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "99B88BED-7F2F-4F89-9BD1-B7EDC1608531"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "859A64AD-1FB2-4A7C-AE4D-26951FC050F9",
"versionEndIncluding": "4.30"
},
{
"criteria": "cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B491E331-B533-4E09-966E-45A3BE724C5A"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "106C6198-C341-4B10-8788-A8FA51F137F1",
"versionEndIncluding": "4.10"
},
{
"criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "38765B0B-9C09-4BC0-9E50-D0C6E8969A77"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cret@cert.org"
}