Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2965▲ 27 respecto a la semana anterior
Críticas / altas1456▲ 193 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)272▼ 254 respecto a la semana anterior
12 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Aplazada | Crítica (9.1) | 0.23% | — | Beckhoff Automation StudioAI | 19/1/2026 | 17/6/2026 | An Improper Certificate Validation vulnerability in the OPC-UA client and ANSL over TLS client used in Automation Studio versions before 6.5 could allow an unauthenticated attacker on the network to position themselves to intercept and interfere with data exchanges. | |
| Analizada | Alta (7.2) | 0.17% | — | Br-automation Automation Studio | 14/5/2024 | 17/6/2026 | Improper DLL loading algorithms in B&R Automation Studio versions >=4.0 and <4.12 may allow an authenticated local attacker to execute code in the context of the product. | |
| Analizada | Alta (8.1) | 0.36% | — | Br-automation Automation StudioBr-automation Technology Guarding | 22/2/2024 | 17/6/2026 | B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data. | |
| Modificada | Alta (7.5) | 0.38% | — | Br-automation Automation Studio | 2/2/2024 | 17/6/2026 | : Relative Path Traversal vulnerability in B&R Industrial Automation Automation Studio allows Relative Path Traversal.This issue affects Automation Studio: from 4.0 through 4.12. | |
| Modificada | Alta (7.8) | 0.15% | — | Br-automation Automation StudioBr-automation Automation Net/pvi | 2/2/2024 | 17/6/2026 | Unquoted Search Path or Element vulnerability in B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI allows Target Programs with Elevated Privileges.This issue affects Automation Studio: from 4.0 through 4.6, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP;… | |
| Modificada | Alta (7.8) | 0.40% | — | Br-automation Automation Studio | 2/2/2024 | 17/6/2026 | Improper Control of Generation of Code ('Code Injection') vulnerability in B&R Industrial Automation Automation Studio allows Local Execution of Code.This issue affects Automation Studio: from 4.0 through 4.12. | |
| Modificada | Alta (8.8) | 0.15% | — | Br-automation Automation Studio | 2/2/2024 | 17/6/2026 | Incorrect Permission Assignment for Critical Resource vulnerability in B&R Industrial Automation Automation Studio allows Privilege Escalation.This issue affects Automation Studio: from 4.6.0 through 4.6.X, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP. | |
| Modificada | Alta (8.6) | 1.2% | — | Deltaww Delta Robot Automation Studio | 31/8/2022 | 17/6/2026 | Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions where the software processes an XML document that can contain XML entities with URIs that resolve to documents outside of the intended sphere of control, causing the product to embed incorrect… | |
| Modificada | Alta (7.5) | 1.3% | — | Br-automation Automation Studio | 29/4/2020 | 17/6/2026 | A directory traversal vulnerability in SharpZipLib used in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x and 4.2.x allow unauthenticated users to write to certain local directories. The vulnerability is also known as zip slip. | |
| Modificada | Media (5.9) | 0.53% | — | Br-automation Automation Studio | 29/4/2020 | 17/6/2026 | A missing secure communication definition and an incomplete TLS validation in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.5SP, < 4.6.4 and < 4.7.2 enable unauthenticated users to perform MITM attacks via the B&R upgrade server. | |
| Modificada | Alta (7.1) | 0.27% | — | Br-automation Automation Studio | 29/4/2020 | 17/6/2026 | A privilege escalation vulnerability in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.4SP, <. 4.6.3SP, < 4.7.2 and < 4.8.1 allow authenticated users to delete arbitrary files via an exposed interface. | |
| Modificada | Crítica (9.4) | 1.6% | — | Br-automation Automation RuntimeBr-automation Automation Studio | 20/4/2020 | 17/6/2026 | An authentication weakness in the SNMP service in B&R Automation Runtime versions 2.96, 3.00, 3.01, 3.06 to 3.10, 4.00 to 4.63, 4.72 and above allows unauthenticated users to modify the configuration of B&R products via SNMP. |