CVE-2020-24682
Estado: ModificadaAlta (7.8)—
Unquoted Search Path or Element vulnerability in B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI allows Target Programs with Elevated Privileges.This issue affects Automation Studio: from 4.0 through 4.6, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP; NET/PVI: from 4.0 through 4.6, from 4.7.0 before 4.7.7, from 4.8.0 before 4.8.6, from 4.9.0 before 4.9.4.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.15%
- Percentil entre todas las CVEs puntuadas: 3
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-428
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2020-24682",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2020-24682",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-02-02T14:19:51.368303Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@ch.abb.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 0.6
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cybersecurity@ch.abb.com",
"affectedData": [
{
"vendor": "B&R Industrial Automation",
"product": "Automation Studio",
"versions": [
{
"status": "affected",
"version": "4.0",
"versionType": "custom",
"lessThanOrEqual": "4.6"
},
{
"status": "affected",
"version": "4.7.0",
"lessThan": "4.7.7 SP",
"versionType": "custom"
},
{
"status": "affected",
"version": "4.8.0",
"lessThan": "4.8.6 SP",
"versionType": "custom"
},
{
"status": "affected",
"version": "4.9.0",
"lessThan": "4.9.4 SP",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "B&R Industrial Automation",
"product": "NET/PVI",
"versions": [
{
"status": "affected",
"version": "4.0",
"versionType": "custom",
"lessThanOrEqual": "4.6"
},
{
"status": "affected",
"version": "4.7.0",
"lessThan": "4.7.7",
"versionType": "custom"
},
{
"status": "affected",
"version": "4.8.0",
"lessThan": "4.8.6",
"versionType": "custom"
},
{
"status": "affected",
"version": "4.9.0",
"lessThan": "4.9.4",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-02-02T08:15:45.573",
"references": [
{
"url": "https://www.br-automation.com/fileadmin/2021-14-BR-AS-NET-PVI-Service-Issues-c3710fbf.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@ch.abb.com"
},
{
"url": "https://www.br-automation.com/fileadmin/2021-14-BR-AS-NET-PVI-Service-Issues-c3710fbf.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@ch.abb.com",
"description": [
{
"lang": "en",
"value": "CWE-428"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unquoted Search Path or Element vulnerability in B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI allows Target Programs with Elevated Privileges.This issue affects Automation Studio: from 4.0 through 4.6, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP; NET/PVI: from 4.0 through 4.6, from 4.7.0 before 4.7.7, from 4.8.0 before 4.8.6, from 4.9.0 before 4.9.4.\n\n"
},
{
"lang": "es",
"value": "Vulnerabilidad de elemento o ruta de búsqueda sin comillas en B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI permite programas de destino con privilegios elevados. Este problema afecta a Automation Studio: desde 4.6.0 hasta 4.6.X, desde 4.7.0 antes de 4.7.7 SP , desde 4.8.0 antes de 4.8.6 SP, desde 4.9.0 antes de 4.9.4 SP; NET/PVI: desde 4.6.0 hasta 4.6.X, desde 4.7.0 antes de 4.7.7, desde 4.8.0 antes de 4.8.6, desde 4.9.0 antes de 4.9.4."
}
],
"lastModified": "2026-06-17T03:05:58.727",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "436F71CF-DD09-4E65-BB95-BF2C4A19E40A",
"versionEndExcluding": "4.7.7.74"
},
{
"criteria": "cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "04F8420B-E58C-4C17-B47B-15356571E650",
"versionEndExcluding": "4.8.6.30",
"versionStartIncluding": "4.8"
},
{
"criteria": "cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0515B5D7-8B71-4D6E-B0E1-4E61B930A54E",
"versionEndExcluding": "4.9.4.92",
"versionStartIncluding": "4.9"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:br-automation:automation_net\\/pvi:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2217CBD5-3C47-48F0-B820-478382164B6A",
"versionEndExcluding": "4.7.7",
"versionStartIncluding": "4.0"
},
{
"criteria": "cpe:2.3:a:br-automation:automation_net\\/pvi:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DD9047EE-9E8A-43F5-8DB5-3AE830E423C3",
"versionEndExcluding": "4.8.6",
"versionStartIncluding": "4.8"
},
{
"criteria": "cpe:2.3:a:br-automation:automation_net\\/pvi:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "742952BE-1FB2-478F-94A7-D32F4A063992",
"versionEndExcluding": "4.9.4",
"versionStartIncluding": "4.9"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@ch.abb.com"
}