CVE-2021-22281
Estado: ModificadaAlta (7.5)—
: Relative Path Traversal vulnerability in B&R Industrial Automation Automation Studio allows Relative Path Traversal.This issue affects Automation Studio: from 4.0 through 4.12.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.38%
- Percentil entre todas las CVEs puntuadas: 29
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-23
- CWE-22
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-22281",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2021-22281",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-08-21T15:56:31.407839Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@ch.abb.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6.3,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 4,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cybersecurity@ch.abb.com",
"affectedData": [
{
"vendor": "B&R Industrial Automation",
"product": "Automation Studio",
"versions": [
{
"status": "affected",
"version": "4.0",
"versionType": "custom",
"lessThanOrEqual": "4.12"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-02-02T08:15:46.013",
"references": [
{
"url": "https://www.br-automation.com/fileadmin/2021-11_ZipSlip_Vulnerability_in_Automation_Studio_Project_Import-b90d2f42.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@ch.abb.com"
},
{
"url": "https://www.br-automation.com/fileadmin/2021-11_ZipSlip_Vulnerability_in_Automation_Studio_Project_Import-b90d2f42.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@ch.abb.com",
"description": [
{
"lang": "en",
"value": "CWE-23"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": ": Relative Path Traversal vulnerability in B&R Industrial Automation Automation Studio allows Relative Path Traversal.This issue affects Automation Studio: from 4.0 through 4.12.\n\n"
},
{
"lang": "es",
"value": ": La vulnerabilidad de Path Traversal en B&R Industrial Automation Automation Studio permite explotar niveles de seguridad de control de acceso configurados incorrectamente. Este problema afecta a Automation Studio: desde 4.0 hasta 4.12."
}
],
"lastModified": "2026-06-17T03:36:55.857",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1C6F1F09-B82E-4E1B-B2FA-CDCC529FA790",
"versionEndIncluding": "4.12",
"versionStartIncluding": "4.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@ch.abb.com"
}