Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2737▼ 484 respecto a la semana anterior
Críticas / altas1302▼ 187 respecto a la semana anterior
Nueva explotación activa (KEV)3▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)227▼ 275 respecto a la semana anterior
435 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 1.6% | — | Advantech WebaccessAdvantech Webaccess DashboardAdvantech Webaccess ScadaAdvantech Webaccess/nms | 15/5/2018 | 17/6/2026 | In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several SQL injection vulnerabilities have been identified, which may allow an attacker to… | |
| Modificada | Crítica (9.8) | 3.7% | — | Advantech WebaccessAdvantech Webaccess DashboardAdvantech Webaccess ScadaAdvantech Webaccess/nms | 15/5/2018 | 17/6/2026 | In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several stack-based buffer overflow vulnerabilities have been identified, which may allow an… | |
| Modificada | Crítica (9.8) | 2.8% | — | Advantech WebaccessAdvantech Webaccess DashboardAdvantech Webaccess ScadaAdvantech Webaccess/nms | 15/5/2018 | 17/6/2026 | In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, several untrusted pointer dereference vulnerabilities have been identified, which may allow an… | |
| Modificada | Alta (7.5) | 2.2% | — | Advantech WebaccessAdvantech Webaccess DashboardAdvantech Webaccess ScadaAdvantech Webaccess/nms | 15/5/2018 | 17/6/2026 | In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an external control of file name or path vulnerability has been identified, which may allow an… | |
| Modificada | Media (6.1) | 0.63% | — | Advantech WebaccessAdvantech Webaccess DashboardAdvantech Webaccess ScadaAdvantech Webaccess/nms | 15/5/2018 | 17/6/2026 | In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an origin validation error vulnerability has been identified, which may allow an attacker can… | |
| Modificada | Alta (7.5) | 1.7% | — | Advantech WebaccessAdvantech Webaccess DashboardAdvantech Webaccess ScadaAdvantech Webaccess/nms | 15/5/2018 | 17/6/2026 | In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an information exposure vulnerability through directory listing has been identified, which may… | |
| Modificada | Crítica (9.8) | 4.0% | — | Advantech WebaccessAdvantech Webaccess DashboardAdvantech Webaccess ScadaAdvantech Webaccess/nms | 15/5/2018 | 17/6/2026 | In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a path transversal vulnerability has been identified, which may allow an attacker to execute… | |
| Modificada | Alta (7.5) | 1.7% | — | Aveva ClearscadaSchneider-electric Clearscada | 14/5/2018 | 17/6/2026 | In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA… | |
| Modificada | Alta (7.8) | 1.9% | — | Spidercontrol Scada Microbrowser | 26/4/2018 | 17/6/2026 | In SpiderControl MicroBrowser Windows XP, Vista 7, 8 and 10, Versions 1.6.30.144 and prior, an uncontrolled search path element vulnerability has been identified which could be exploited by placing a specially crafted DLL file in the search path. If the malicious DLL is loaded prior to the valid DLL, an attacker could… | |
| Modificada | Media (5.3) | 8.5% | 💥 Exploit | Lcds Laquis Scada | 17/4/2018 | 17/6/2026 | Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize external input to ensure that users are not calling for absolute path sequences outside of their privilege level. | |
| Modificada | Alta (7.8) | 0.42% | — | Lcds Laquis Scada | 9/4/2018 | 17/6/2026 | A structured exception handler overflow vulnerability in Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA 4.1.0.3391 and earlier may allow code execution. | |
| Modificada | Alta (7.8) | 0.57% | — | Rapidscada Rapid Scada | 8/3/2018 | 17/6/2026 | A vulnerability allows local attackers to escalate privilege on Rapid Scada 5.5.0 because of weak C:\SCADA permissions. The specific flaw exists within the access control that is set and modified during the installation of the product. The product sets weak access control restrictions. An attacker can leverage this… | |
| Modificada | Alta (7.8) | 0.38% | — | Schneider-electric Interactive Graphical Scada System | 12/2/2018 | 17/6/2026 | A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security. | |
| Modificada | Alta (8.1) | 0.47% | — | Schneider-electric Powerscada Anywhere | 12/2/2018 | 17/6/2026 | A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social… | |
| Modificada | Media (5.3) | 1.8% | — | Advantech Webaccess/scada | 25/1/2018 | 17/6/2026 | A Path Traversal issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. An attacker has read access to files within the directory structure of the target device. | |
| Modificada | Media (5.3) | 1.2% | — | Advantech Webaccess/scada | 25/1/2018 | 17/6/2026 | A SQL Injection issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. WebAccess/SCADA does not properly sanitize its inputs for SQL commands. | |
| Modificada | Media (6.1) | 0.89% | — | Geovap Reliance-scada | 4/12/2017 | 17/6/2026 | A Cross-site Scripting issue was discovered in Geovap Reliance SCADA Version 4.7.3 Update 2 and prior. This vulnerability could allow an unauthenticated attacker to inject arbitrary code. | |
| Modificada | Alta (7.8) | 0.29% | — | Trihedral Vtscada | 6/11/2017 | 17/6/2026 | An Improper Access Control issue was discovered in Trihedral VTScada 11.3.03 and prior. A local, non-administrator user has privileges to read and write to the file system of the target machine. | |
| Modificada | Alta (7.8) | 0.93% | — | Trihedral Vtscada | 6/11/2017 | 17/6/2026 | An Uncontrolled Search Path Element issue was discovered in Trihedral VTScada 11.3.03 and prior. The program will execute specially crafted malicious dll files placed on the target machine. | |
| Modificada | Alta (7.8) | 0.73% | — | Myscada Mypro | 6/10/2017 | 17/6/2026 | An Unquoted Search Path issue was discovered in mySCADA myPRO Versions 7.0.26 and prior. Application services utilize unquoted search path elements, which could allow an attacker to execute arbitrary code with elevated privileges. | |
| Modificada | Media (6.8) | 0.75% | — | Intelligent Platforms Proficy Hmi/scada Cimplicity | 5/10/2017 | 17/6/2026 | A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution. | |
| Modificada | Alta (7.8) | 0.39% | — | Spidercontrol Scada Webserver | 5/10/2017 | 17/6/2026 | An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current… | |
| Modificada | Alta (7.5) | 1.0% | — | Aveva Clearscada | 26/9/2017 | 17/6/2026 | Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malformed requests can be sent to ClearSCADA client applications to cause unexpected behavior. Client applications affected include ViewX and the Server Icon. | |
| Modificada | Media (5.5) | 0.46% | — | Schneider-electric Powerscada AnywhereSchneider-electric Citect Anywhere | 26/9/2017 | 17/6/2026 | A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to escape out of remote PowerSCADA Anywhere applications and launch other processes. | |
| Modificada | Media (6.5) | 0.78% | — | Schneider-electric Powerscada AnywhereSchneider-electric Citect Anywhere | 26/9/2017 | 17/6/2026 | A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the use of outdated cipher suites and improper verification of peer SSL Certificate. |