Estado: ModificadaAlta (7.8)—
A vulnerability allows local attackers to escalate privilege on Rapid Scada 5.5.0 because of weak C:\SCADA permissions. The specific flaw exists within the access control that is set and modified during the installation of the product. The product sets weak access control restrictions. An attacker can leverage this vulnerability to execute arbitrary code under the context of Administrator, the IUSR account, or SYSTEM.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.57%
- Percentil entre todas las CVEs puntuadas: 45
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-732
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2018-5313",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.2,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": true,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2018-03-08T20:29:00.377",
"references": [
{
"url": "http://packetstormsecurity.com/files/146668/Rapid-Scada-5.5.0-Insecure-Permissions.html",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cve@mitre.org"
},
{
"url": "http://seclists.org/fulldisclosure/2018/Mar/11",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "http://packetstormsecurity.com/files/146668/Rapid-Scada-5.5.0-Insecure-Permissions.html",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://seclists.org/fulldisclosure/2018/Mar/11",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability allows local attackers to escalate privilege on Rapid Scada 5.5.0 because of weak C:\\SCADA permissions. The specific flaw exists within the access control that is set and modified during the installation of the product. The product sets weak access control restrictions. An attacker can leverage this vulnerability to execute arbitrary code under the context of Administrator, the IUSR account, or SYSTEM."
},
{
"lang": "es",
"value": "Una vulnerabilidad permite que atacantes locales escalen privilegios en Rapid Scada 5.5.0 debido a permisos C:\\SCADA débiles. Este error en concreto existe en el control de acceso que se establece y modifica durante la instalación del producto. El producto establece controles de acceso débiles. Un atacante podría aprovecharse de esta vulnerabilidad para ejecutar código arbitrario bajo el contexto del Administrador, la cuenta IUSR o SYSTEM."
}
],
"lastModified": "2026-06-17T02:00:01.540",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rapidscada:rapid_scada:5.5.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "00C4E6AA-822F-4506-9EF2-FD60B1D605EB"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}