CVE-2017-9963
Estado: ModificadaAlta (8.1)—
A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.47%
- Percentil entre todas las CVEs puntuadas: 39
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-352
Referencias
- http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/
- https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere
- http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/
- https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-9963",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 4.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2018-02-12T23:29:00.213",
"references": [
{
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/",
"tags": [
"Broken Link"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/",
"tags": [
"Broken Link"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-352"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 for multiple state-changing requests. This type of attack requires some level of social engineering in order to get a legitimate user to click on or access a malicious link/site containing the CSRF attack."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de Cross-Site Request Forgery (CSRF) en el componente Secure Gateway de PowerSCADA Anywhere v1.0 redistribuido con PowerSCADA Expert v8.1 y PowerSCADA Expert v8.2 y Citect Anywhere versión 1.0, de Schneider Electric para múltiples peticiones de cambio de estado. Este tipo de ataque requiere cierto nivel de ingeniería social para conseguir que un usuario legítimo haga clic o acceda a un enlace o página maliciosa que contenga el ataque CSRF."
}
],
"lastModified": "2026-06-17T01:29:17.713",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:powerscada_anywhere:1.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6445511E-70B8-4E03-A178-FFDBE02E1609"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}