Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2740▼ 483 respecto a la semana anterior
Críticas / altas1302▼ 188 respecto a la semana anterior
Nueva explotación activa (KEV)3▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)227▼ 275 respecto a la semana anterior
787 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (5.7) | 12% | — | Schneider-electric C-bus Toolkit | 21/7/2021 | 17/6/2026 | A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system. | |
| Modificada | Alta (7.8) | 0.94% | — | Schneider-electric Sosafe Configurable | 21/7/2021 | 17/6/2026 | A CWE-502: Deserialization of Untrusted Data vulnerability exists that could cause code execution by opening a malicious project file. | |
| Modificada | Alta (7.5) | 0.80% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-759: Use of a One-Way Hash without a Salt vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could lead an attacker to get… | |
| Modificada | Media (6.5) | 0.83% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-620: Unverified Password Change vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker connected to the… | |
| Modificada | Crítica (9.8) | 1.5% | — | Schneider-electric T200i FirmwareSchneider-electric T200e FirmwareSchneider-electric T200p Firmware | 21/7/2021 | 17/6/2026 | A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when authentication is… | |
| Modificada | Alta (7.3) | 1.1% | — | Schneider-electric Easergy T300 Firmware | 21/7/2021 | 17/6/2026 | A CWE-1236: Improper Neutralization of Formula Elements in a CSV File vulnerability exists in Easergy T300 with firmware V2.7.1 and older that would allow arbitrary command execution. | |
| Modificada | Media (6.5) | 1.1% | — | Schneider-electric Easergy T300 Firmware | 21/7/2021 | 17/6/2026 | A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information. | |
| Modificada | Crítica (9.8) | 1.4% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized… | |
| Modificada | Crítica (9.8) | 1.8% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain… | |
| Modificada | Media (6.5) | 1.1% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials… | |
| Modificada | Crítica (9.8) | 1.4% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized… | |
| Modificada | Alta (8.1) | 1.00% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to perform… | |
| Modificada | Media (6.1) | 0.75% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart… | |
| Modificada | Media (5.4) | 0.48% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Stored Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior… | |
| Modificada | Media (5.3) | 0.95% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to get limited knowledge… | |
| Modificada | Alta (7.2) | 0.65% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an… | |
| Modificada | Crítica (9.8) | 65% | 💥 Exploit | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue… | |
| Modificada | Media (6.1) | 0.76% | — | Schneider-electric Evlink City Evc1s22p4 FirmwareSchneider-electric Evlink City Evc1s7p4 FirmwareSchneider-electric Evlink Parking Evw2 FirmwareSchneider-electric Evlink Parking Evf2 Firmware+2 | 21/7/2021 | 17/6/2026 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8… | |
| Modificada | Media (5.5) | 0.11% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect | 14/7/2021 | 17/6/2026 | Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could… | |
| Modificada | Media (5.5) | 0.24% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect | 14/7/2021 | 17/6/2026 | Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could… | |
| Modificada | Alta (7.1) | 0.22% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect | 14/7/2021 | 17/6/2026 | Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could… | |
| Modificada | Crítica (9.1) | 1.0% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric RemoteconnectSchneider-electric Modicon M580 Bmep581020 Firmware+28 | 14/7/2021 | 17/6/2026 | Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70… | |
| Modificada | Alta (7.1) | 0.22% | — | Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect | 14/7/2021 | 17/6/2026 | Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could… | |
| Modificada | Media (4.3) | 0.65% | — | Schneider-electric Easergy T300 Firmware | 11/6/2021 | 29/6/2026 | A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restricted or incorrectly restricted. | |
| Modificada | Crítica (9.8) | 2.7% | — | Schneider-electric Powerlogic Egx100 FirmwareSchneider-electric Powerlogic Egx300 Firmware | 11/6/2021 | 17/6/2026 | A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767 |