« Volver al listado

CVE-2021-22706

Estado: ModificadaMedia (6.1)—

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (6)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2021-22706",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )",
          "versions": [
            {
              "status": "affected",
              "version": "EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 )"
            }
          ]
        }
      ]
    }
  ],
  "published": "2021-07-21T15:15:14.133",
  "references": [
    {
      "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server."
    },
    {
      "lang": "es",
      "value": "A CWE-79: Se presenta una vulnerabilidad de Neutralización Inapropiada de Entradas Durante la Generación de Páginas Web (\"Cross-site Scripting\") en EVlink City (EVC1S22P4 / EVC1S7P4 todas las versiones anteriores a R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 todas las versiones anteriores a R8 V3.4.0.1), y EVlink Smart Wallbox (EVB1A todas las versiones anteriores a R8 V3.4.0.1) que podría permitir a un atacante hacerse pasar por el usuario que administra la estación de carga o realizar acciones en su nombre cuando se envían parámetros maliciosos diseñados al servidor web de la estación de carga"
    }
  ],
  "lastModified": "2026-06-17T03:37:36.103",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "28E02076-32CB-4729-B7D1-ACD0A5344A67",
              "versionEndExcluding": "r8_v3.4.0.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "AA9F3DA4-C027-4210-8A2B-87121373CE60"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "243AD74C-064A-49E4-9233-296C090AF0FB",
              "versionEndExcluding": "r8_v3.4.0.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C224B6C5-BCA4-400A-A50E-017843825356"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3B6C21FB-1F08-4E28-81A8-489B7A64D1AA",
              "versionEndExcluding": "r8_v3.4.0.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "58F33653-E41D-499A-BD44-0D294C003D7B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8EB862A8-30DC-4CCF-B88D-853CCC045080",
              "versionEndExcluding": "r8_v3.4.0.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B266B002-6C10-4E0B-B14C-9C0A55070CD8"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:evlink_parking_ev.2_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "91F956D0-DFA0-4E31-88F8-DCB304CDF794",
              "versionEndExcluding": "r8_v3.4.0.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:evlink_parking_ev.2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "84800086-3C16-4C24-B64C-C9959089F903"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B910950C-FF66-47D6-B951-A0EC8556E2F5",
              "versionEndExcluding": "r8_v3.4.0.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CC5D698C-6161-4F6D-94CE-01A0ECA95C47"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}