CVE-2021-22778
Estado: ModificadaAlta (7.1)—
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
- Puntuación base: 7.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.22%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-522
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2021-22778",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 3.6,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 4.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.1,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.2,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "n/a",
"product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions",
"versions": [
{
"status": "affected",
"version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions"
}
]
}
]
}
],
"published": "2021-07-14T15:15:08.173",
"references": [
{
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-522"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de credenciales insuficientemente protegidas en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluyéndo todas las versiones de Unity Pro), EcoStruxure Process Expert (todas las versiones, incluyéndo todas las versiones de EcoStruxure Hybrid DCS) y SCADAPack RemoteConnect for x70, todas las versiones, que podría causar una lectura o modificación de bloques de función derivados protegidos por parte de usuarios no autorizados cuando se accede a un archivo de proyecto"
}
],
"lastModified": "2026-06-17T03:37:45.470",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "43140BF9-455B-4E3C-BF5E-BB9BBF9802D2",
"versionEndExcluding": "15.0"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A9BF2D84-901E-4D34-941F-FFAB85B0E9D3"
},
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FD97669F-93D5-42C4-BFC4-1993867F5911"
},
{
"criteria": "cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*",
"vulnerable": true,
"matchCriteriaId": "2D7E0B75-171E-4A73-B722-13473CE1B9D7"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}