Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2743▲ 32 respecto a la semana anterior
Críticas / altas1477▲ 367 respecto a la semana anterior
Nueva explotación activa (KEV)7▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)64▼ 462 respecto a la semana anterior
6 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Analizada | Crítica (9.9) | 4.1% | — | Apache Continuum | 26/1/2026 | 17/6/2026 | ** UNSUPPORTED WHEN ASSIGNED ** Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Apache Continuum. This issue affects Apache Continuum: all versions. Attackers with access to the installations REST API can use this to invoke arbitrary commands on the server. As this… | |
| Modificada | Media (6.1) | 0.80% | — | Schneider-electric Andover Continuum 9680 FirmwareSchneider-electric Andover Continuum 5740 FirmwareSchneider-electric Andover Continuum 5720 FirmwareSchneider-electric Andover Continuum Bcx4040 Firmware+7 | 23/3/2020 | 17/6/2026 | A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server. | |
| Modificada | Media (6.1) | 0.79% | — | Schneider-electric Andover Continuum 9680 FirmwareSchneider-electric Andover Continuum 5740 FirmwareSchneider-electric Andover Continuum 5720 FirmwareSchneider-electric Andover Continuum Bcx4040 Firmware+7 | 23/3/2020 | 17/6/2026 | A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server. | |
| Modificada | Crítica (9.8) | 1.5% | — | Schneider-electric Andover Continuum 9680 FirmwareSchneider-electric Andover Continuum 5740 FirmwareSchneider-electric Andover Continuum 5720 FirmwareSchneider-electric Andover Continuum Bcx4040 Firmware+7 | 23/3/2020 | 17/6/2026 | A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data. | |
| Modificada | Media (6.1) | 0.64% | — | Schneider-electric Andover Continuum 9680 FirmwareSchneider-electric Andover Continuum 5740 FirmwareSchneider-electric Andover Continuum 5720 FirmwareSchneider-electric Andover Continuum Bcx4040 Firmware+7 | 20/11/2019 | 17/6/2026 | A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server. | |
| Modificada | Media (4.3) | 4.2% | — | Apache ContinuumApache Archiva | 17/2/2011 | 16/6/2026 | Cross-site scripting (XSS) vulnerability in Apache Continuum 1.1 through 1.2.3.1, 1.3.6, and 1.4.0 Beta; and Archiva 1.3.0 through 1.3.3 and 1.0 through 1.22 allows remote attackers to inject arbitrary web script or HTML via a crafted parameter, related to the autoIncludeParameters setting for the extremecomponents… |