« Volver al listado

CVE-2020-7481

Estado: ModificadaMedia (6.1)—

A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (11)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-7481",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 4.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 2.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 6.1,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "Andover Continuum (All versions)",
          "versions": [
            {
              "status": "affected",
              "version": "Andover Continuum (All versions)"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-03-23T20:15:12.620",
  "references": [
    {
      "url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-04/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server."
    },
    {
      "lang": "es",
      "value": "Una CWE-79: Se presenta una vulnerabilidad de Neutralización Inapropiada de la Entrada Durante la Generación de Páginas Web (\"Cross-site Scripting\") en Andover Continuum (Todas las versiones), lo que podría permitir un ataque de tipo Cross-site Scripting (ataque XSS) con éxito cuando se usa el servidor web de los productos."
    }
  ],
  "lastModified": "2026-06-17T03:24:51.977",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9680_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6D3343D3-10EA-47A1-9EEC-B8348501BED3"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9680:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "ADB64C97-4C76-4EA1-81BA-BECABB36882F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_5740_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "911CF8D9-F392-400A-81F0-B55EE724C53F"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_5740:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D425EDA6-288C-4F66-B1E8-D47B52C45371"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_5720_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "88E57181-1965-43F3-BD32-7ADB655353C6"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_5720:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "AD829769-A8A2-4362-83F0-DD8C0C66124C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_bcx4040_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A7FC4EFC-3227-498A-A387-456AA33D2668"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_bcx4040:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "3CB3D1AD-9BAE-4DA5-B32B-63F1A2FEE30B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_bcx9640_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5AD56546-BE9B-4AC1-8B28-F6F8EA856607"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_bcx9640:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "1A0F10A1-AC1F-425B-90D4-ECFFEFF8A6F4"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9900_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "406F67ED-EBC8-45CB-8281-CC373BDCEA59"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9900:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "49764811-1299-4612-B19E-5D9BE4005186"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9940_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8B03092B-591B-42D6-A3FA-5895C298920B"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9940:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7C7C825C-CAB3-4465-B7B8-380E1A20AC0A"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9941_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "858DC6FD-DCAB-47E8-8795-F86EBC855925"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9941:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8AD997D7-5A18-4983-BA8C-D29AA27843C6"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9924_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "453385B9-4E12-4C66-9F0A-22317444E60F"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9924:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "2FB35B6B-69DC-4A8A-AE3E-CA9A6127B080"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9702_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "04246590-7180-4B1B-B75A-09CEACFE1CE3"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9702:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4F721BC6-0CA1-4431-853D-B2D923A66751"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:andover_continuum_9200_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BBFA71DD-1640-4C78-A902-2DCE7E369EE8"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:andover_continuum_9200:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "2DE93F39-BF30-42EF-8387-4C060F075D49"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}