CVE-2026-9650
CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.
Timeline
Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.
- CVE record published in NVD
- Record last modified in NVD
ATT&CK techniques
How this vulnerability is exploited and what the attacker gains, in MITRE ATT&CK terms.
- Exploitation
T1190Exploit Public-Facing Applicationinitial access75 % - Primary impact
T1552Unsecured Credentialscredential access85 % - Secondary impact
T1078Valid Accountsstealth · persistence · privilege escalation · initial access70 %
AV:N/PR:N sin interacción permite acceso remoto a credenciales en firmware (CWE-522). Las credenciales expuestas (T1552) permiten acceso posterior con cuenta válida (T1078).
Inferred by our analysis agent from the official description, CVSS vector and CWE, and checked by a supervisor. May contain errors.
ATT&CK mitigations that cover these techniques
Affected technologies (2)
NVD record
- NVD status
- Analyzed
- Published
- Jun 25, 2026
- Last modified
- Jul 14, 2026
- CVSS vector
- CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Weakness (CWE)
- CWE-522
References
- Vendor advisorydownload.schneider-electric.com/files
Raw JSON (NVD)
Show
{
"id": "CVE-2026-9650",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-9650",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-06-25T15:48:51.280291Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.7,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller",
"versions": [
{
"status": "affected",
"version": "Version 11.06.30 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Saitel DP Remote Terminal Unit & Controller",
"versions": [
{
"status": "affected",
"version": "Version 11.06.35 and prior"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2026-06-25T16:16:43.867",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-160-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-160-02.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-522"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device."
}
],
"lastModified": "2026-07-14T16:00:24.510",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:easylogic_t150_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6D498A9B-1593-41C1-BB95-F7815F01087D",
"versionEndExcluding": "11.06.32"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:easylogic_t150:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E3B30463-195D-4D26-BC9E-9BA0D9BBB862"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:saitel_dp_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "71B582C0-A3F2-4E6F-B2CE-E77ACB81F59F",
"versionEndExcluding": "11.06.38"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:saitel_dp:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E6D73382-1957-4CC7-953F-D57C005D63B0"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}