« Volver al listado

Schneider-electric

Schneider-electric Saitel DP Firmware: vulnerabilidades y CVE

Schneider-electric Saitel DP Firmware tiene 7 vulnerabilidades publicadas, 2 de ellas en los últimos 12 meses. 1 son críticas y 0 figuran en el catálogo de explotación activa de CISA.

CVE7
Últimos 12 meses2
Críticas1
Explotadas activamente0

Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología

Últimas vulnerabilidades

CVESeveridadEPSSExplotación activaPublicadaDescripción
CVE-2026-9651Media (6.7)0.16%—25 jun 2026
CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access…
CVE-2026-9650Alta (8.7)0.41%—25 jun 2026
CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system…
CVE-2020-25184Media (5.5)0.44%—18 mar 2022
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable…
CVE-2020-25182Media (6.7)0.45%—18 mar 2022
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary…
CVE-2020-25180Media (6.5)1.2%—18 mar 2022
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of…
CVE-2020-25178Alta (8.8)1.7%—18 mar 2022
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications.…
CVE-2020-25176Crítica (9.8)6.4%—18 mar 2022
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not…

🎯 Cómo se explota (técnicas ATT&CK)

  1. T1190 Exploit Public-Facing Application1
  2. T1552 Unsecured Credentials1

Número de CVE de esta tecnología asignadas a cada técnica de explotación o de impacto principal.