CVE-2022-3752

High (7.5)—
Schedule the patchSeverity High 7.5. No public exploit or active exploitation known.
Severity7.5High · CVSS 3.1
Exploitation probability1.01 %higher than 62% of CVEs · score from Nov 25, 2026
Active exploitationNonot in the CISA catalog · checked Nov 25, 05:00 PM
Public exploitNot knownno public code found

An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online and continue normal operation.

Timeline

Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.

  1. CVE record published in NVD
  2. Record last modified in NVD

Affected technologies (5)

NVD record

NVD status
Modified
Published
Dec 19, 2022
Last modified
Jun 17, 2026
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness (CWE)
CWE-20

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2022-3752",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2022-3752",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-04-16T14:27:21.670498Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "PSIRT@rockwellautomation.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 8.6,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 4,
        "exploitabilityScore": 3.9
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "PSIRT@rockwellautomation.com",
      "affectedData": [
        {
          "vendor": "Rockwell Automation",
          "product": "CompactLogix 5480",
          "versions": [
            {
              "status": "affected",
              "version": "32.011 and later"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Rockwell Automation",
          "product": "ControlLogix 5580 ",
          "versions": [
            {
              "status": "affected",
              "version": "31.011 and later"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Rockwell Automation",
          "product": "GuardLogix 5580",
          "versions": [
            {
              "status": "affected",
              "version": "31.011 and later"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Rockwell Automation",
          "product": "Compact GuardLogix 5380",
          "versions": [
            {
              "status": "affected",
              "version": "31.011 and later"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Rockwell Automation",
          "product": "CompactLogix 5380",
          "versions": [
            {
              "status": "affected",
              "version": "31.011 and later"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2022-12-19T23:15:10.660",
  "references": [
    {
      "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137664",
      "tags": [
        "Permissions Required",
        "Vendor Advisory"
      ],
      "source": "PSIRT@rockwellautomation.com"
    },
    {
      "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137664",
      "tags": [
        "Permissions Required",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "PSIRT@rockwellautomation.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic \nloading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload \nthe user project file to bring the device back online and continue normal operation.\n\n\n"
    },
    {
      "lang": "es",
      "value": "Un usuario no autorizado podría utilizar una secuencia especialmente manipulada de mensajes Ethernet/IP, combinada con una gran carga de tráfico, para provocar una condición de Denegación de Servicio (DoS) en los controladores Logix de Rockwell Automation, lo que provocaría una falla importante no recuperable. Si el dispositivo de destino deja de estar disponible, el usuario tendría que borrar la falla y volver a descargar el archivo de proyecto del usuario para volver a poner el dispositivo en línea y continuar con el funcionamiento normal."
    }
  ],
  "lastModified": "2026-06-17T05:00:14.520",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A3BB8945-AC46-463C-A7D9-15584AD0FA68",
              "versionStartIncluding": "32.011"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "80F4F5BE-07DF-402A-BF98-34FBA6A11968"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5580_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "EDD27C92-CC9B-4780-B7AC-8ECBE1FF7C77",
              "versionStartIncluding": "31.011"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5580:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CEA62D6E-168F-4EEC-9E90-C679273C1CDB"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "25846D71-4F46-4C50-BB76-5D692DE9ACFE",
              "versionStartIncluding": "32.011"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "006B7683-9FDF-4748-BA28-2EA22613E092"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E187CC9F-3BFC-4AE3-A4E5-477416A16E24",
              "versionStartIncluding": "31.011"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "62414E65-73C7-4172-B7BF-F40A66AFBB90"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "65D5D8EB-6A19-4849-988D-C3F65071B05F",
              "versionStartIncluding": "31.011"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "PSIRT@rockwellautomation.com"
}