« Volver al listado

Rockwellautomation

Rockwellautomation Compactlogix 5480 Firmware: vulnerabilidades y CVE

Rockwellautomation Compactlogix 5480 Firmware tiene 11 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 1 son críticas y 0 figuran en el catálogo de explotación activa de CISA.

CVE11
Últimos 12 meses0
Críticas1
Explotadas activamente0

Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología

Últimas vulnerabilidades

CVESeveridadEPSSExplotación activaPublicadaDescripción
CVE-2024-6207Alta (8.7)0.55%—14 oct 2024
CVE 2021-22681 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1550.html and send a specially crafted CIP message to the device. If exploited, a threat actor could help prevent…
CVE-2024-8626Alta (8.7)0.52%—8 oct 2024
Due to a memory leak, a denial-of-service vulnerability exists in the Rockwell Automation affected products. A malicious actor could exploit this vulnerability by performing multiple actions on certain web pages of the…
CVE-2024-6077Alta (8.7)0.56%—12 sept 2024
A denial-of-service vulnerability exists in the Rockwell Automation affected products when specially crafted packets are sent to the CIP Security Object. If exploited the device will become unavailable and require a…
CVE-2024-7515Alta (8.7)0.52%—14 ago 2024
CVE-2024-7515 IMPACT A denial-of-service vulnerability exists in the affected products. A malformed PTP management packet can cause a major nonrecoverable fault in the controller.
CVE-2024-7507Alta (8.7)0.50%—14 ago 2024
CVE-2024-7507 IMPACT A denial-of-service vulnerability exists in the affected products. This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller.
CVE-2024-5659Alta (8.3)0.31%—14 jun 2024
Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending…
CVE-2024-3493Alta (7.5)0.64%—15 abr 2024
A specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation's ControlLogix…
CVE-2022-3752Alta (7.5)1.3%—19 dic 2022
An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a…
CVE-2022-1797Alta (8.6)2.1%—2 jun 2022
A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target…
CVE-2022-1161Crítica (9.8)5.2%—11 abr 2022
An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a…
CVE-2022-1159Alta (7.2)3.5%—1 abr 2022
Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code…

🎯 Cómo se explota (técnicas ATT&CK)

  1. T1190 Exploit Public-Facing Application2
  2. T1499.004 Application or System Exploitation2

Número de CVE de esta tecnología asignadas a cada técnica de explotación o de impacto principal.

Otros productos de Rockwellautomation