« Volver al listado

CVE-2020-12005

Estado: ModificadaAlta (7.5)—

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-12005",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 6.9,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software",
          "versions": [
            {
              "status": "affected",
              "version": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-06-15T20:15:11.473",
  "references": [
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-434"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-434"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition."
    },
    {
      "lang": "es",
      "value": "FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. Se presenta una vulnerabilidad en la función de comunicación que permite a los usuarios cargar archivos EDS mediante FactoryTalk Linx. Esto puede permitir a un atacante cargar un archivo con mala compresión, consumiendo todos los recursos de CPU disponibles, conllevando a una condición de denegación de servicio"
    }
  ],
  "lastModified": "2026-06-17T02:51:14.337",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.00:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "244B67F2-DEC2-44E2-94F1-F6A82249453C"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "767F223A-C4CE-49DE-B66F-51345E91C98F"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.11:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5675EA61-1854-4AA1-BA1B-E07442E1F10C"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4F6780E2-AB8D-4860-812F-CBE82A94EF0D",
              "versionEndIncluding": "4.11.00"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}