CVE-2020-12005

High (7.5)—
Schedule the patchSeverity High 7.5. No public exploit or active exploitation known.
Severity7.5High · CVSS 3.1
Exploitation probability1.84 %higher than 80% of CVEs · score from Nov 25, 2026
Active exploitationNonot in the CISA catalog · checked Nov 25, 05:00 PM
Public exploitNot knownno public code found

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.

Timeline

Built from our own data: NVD, CISA KEV and other exploitation catalogues, FIRST EPSS, public exploits, specialised media and Orbitaley coverage.

  1. CVE record published in NVD
  2. Record last modified in NVD

Affected technologies (2)

NVD record

NVD status
Modified
Published
Jun 15, 2020
Last modified
Jun 17, 2026
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness (CWE)
CWE-434

References

Raw JSON (NVD)

Show
{
  "id": "CVE-2020-12005",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "authentication": "NONE",
          "integrityImpact": "NONE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "NONE"
        },
        "acInsufInfo": false,
        "impactScore": 6.9,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software",
          "versions": [
            {
              "status": "affected",
              "version": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-06-15T20:15:11.473",
  "references": [
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-434"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-434"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition."
    },
    {
      "lang": "es",
      "value": "FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. Se presenta una vulnerabilidad en la función de comunicación que permite a los usuarios cargar archivos EDS mediante FactoryTalk Linx. Esto puede permitir a un atacante cargar un archivo con mala compresión, consumiendo todos los recursos de CPU disponibles, conllevando a una condición de denegación de servicio"
    }
  ],
  "lastModified": "2026-06-17T02:51:14.337",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.00:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "244B67F2-DEC2-44E2-94F1-F6A82249453C"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "767F223A-C4CE-49DE-B66F-51345E91C98F"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.11:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5675EA61-1854-4AA1-BA1B-E07442E1F10C"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4F6780E2-AB8D-4860-812F-CBE82A94EF0D",
              "versionEndIncluding": "4.11.00"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}