« Volver al listado

Rockwellautomation

Rockwellautomation Rslinx Classic: vulnerabilidades y CVE

Rockwellautomation Rslinx Classic tiene 10 vulnerabilidades publicadas, 4 de ellas en los últimos 12 meses. 2 son críticas y 0 figuran en el catálogo de explotación activa de CISA.

CVE10
Últimos 12 meses4
Críticas2
Explotadas activamente0

Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología

Últimas vulnerabilidades

CVESeveridadEPSSExplotación activaPublicadaDescripción
CVE-2026-9625Alta (8.7)0.43%—1 sept 2026
A denial-of-service security issue exists within RSLinx® Classic. A crafted CIP packet with an oversized embedded message request can cause the RSLinx® Classic service to crash, requiring a restart of the service to…
CVE-2026-9624Alta (8.7)0.43%—1 sept 2026
A denial-of-service security issue exists within RSLinx® Classic. A crafted CIP packet can cause the RSLinx® Classic service to crash due to insufficient data length validation, requiring a restart of the service to…
CVE-2026-9622Alta (8.7)0.43%—1 sept 2026
A denial-of-service security issue exists within RSLinx® Classic. A crafted CIP packet targeting the Forward Close service can cause the RSLinx® Classic service to crash, requiring a restart of the service to recover.
CVE-2026-9621Crítica (9.2)0.43%—1 sept 2026
A denial-of-service security issue exists within RSLinx® Classic. The security issue stems from improper handling of a malformed packet. A crafted CIP packet can cause the RSLinx® Classic service to crash, requiring a…
CVE-2020-12005Alta (7.5)1.8%—15 jun 2020
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later,…
CVE-2020-12003Alta (7.5)5.2%—15 jun 2020
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later,…
CVE-2020-12001Crítica (9.8)12%—15 jun 2020
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later,…
CVE-2020-11999Alta (8.1)2.8%—15 jun 2020
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later,…
CVE-2020-10642Alta (7.8)0.45%—13 abr 2020
In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening…
CVE-2018-10619Alta (7.8)2.8%—7 jun 2018
An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code…

🎯 Cómo se explota (técnicas ATT&CK)

  1. T1190 Exploit Public-Facing Application4
  2. T1499.004 Application or System Exploitation4

Número de CVE de esta tecnología asignadas a cada técnica de explotación o de impacto principal.

Otros productos de Rockwellautomation