« Volver al listado

CVE-2020-11999

Estado: ModificadaAlta (8.1)—

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2020-11999",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N",
          "authentication": "SINGLE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 4.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software",
          "versions": [
            {
              "status": "affected",
              "version": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior"
            }
          ]
        }
      ]
    }
  ],
  "published": "2020-06-15T20:15:11.223",
  "references": [
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "ics-cert@hq.dhs.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data."
    },
    {
      "lang": "es",
      "value": "FactoryTalk Linx versiones 6.00, 6.10 y 6.11, RSLinx Classic versiones v4.11.00 y anteriores, Connected Components Workbench: versión 12 y anteriores, ControlFLASH: versión 14 y posteriores, ControlFLASH Plus: versión 1 y posteriores, FactoryTalk Asset Center: versión 9 y posteriores , FactoryTalk Linx CommDTM: versión 1 y posteriores, Studio 5000 Launcher: versión 31 y posteriores a Stud, software 5000 Logix Designer: versión 32 y anteriores son vulnerables. Una llamada expuesta de la API permite a los usuarios proporcionar archivos a ser procesados sin saneamiento. Esto puede permitir a un atacante especificar un nombre de archivo para ejecutar código no autorizado y modificar archivos o datos"
    }
  ],
  "lastModified": "2026-06-17T02:51:13.667",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.00:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "244B67F2-DEC2-44E2-94F1-F6A82249453C"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "767F223A-C4CE-49DE-B66F-51345E91C98F"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.11:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5675EA61-1854-4AA1-BA1B-E07442E1F10C"
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4F6780E2-AB8D-4860-812F-CBE82A94EF0D",
              "versionEndIncluding": "4.11.00"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}