« Volver al listado

Siemens

Siemens 7KT Pac1260 Data Manager Firmware: vulnerabilidades y CVE

Siemens 7KT Pac1260 Data Manager Firmware tiene 9 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 5 son críticas y 0 figuran en el catálogo de explotación activa de CISA.

CVE9
Últimos 12 meses0
Críticas5
Explotadas activamente0

Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología

Últimas vulnerabilidades

CVESeveridadEPSSExplotación activaPublicadaDescripción
CVE-2024-41796Media (6.9)0.38%—8 abr 2025
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices allows to change the login password without knowing the current password. In combination with…
CVE-2024-41795Media (6.9)0.21%—8 abr 2025
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices is vulnerable to Cross-Site Request Forgery (CSRF) attacks. This could allow an…
CVE-2024-41794Crítica (10)0.62%—8 abr 2025
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could…
CVE-2024-41793Alta (7.7)0.54%—8 abr 2025
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices provides an endpoint that allows to enable the ssh service without authentication. This could…
CVE-2024-41792Crítica (9.2)0.57%—8 abr 2025
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices contains a path traversal vulnerability. This could allow an unauthenticated attacker it to…
CVE-2024-41791Media (6.9)0.38%—8 abr 2025
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not authenticate report creation requests. This could allow an unauthenticated remote…
CVE-2024-41790Crítica (9.4)0.89%—8 abr 2025
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the region parameter in specific POST requests. This could allow an…
CVE-2024-41789Crítica (9.4)0.89%—8 abr 2025
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the language parameter in specific POST requests. This could allow an…
CVE-2024-41788Crítica (9.4)0.89%—8 abr 2025
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the input parameters in specific GET requests. This could allow an…

🎯 Cómo se explota (técnicas ATT&CK)

  1. T1059 Command and Scripting Interpreter3
  2. T1190 Exploit Public-Facing Application3
  3. T1210 Exploitation of Remote Services3
  4. T1005 Data from Local System1
  5. T1078 Valid Accounts1
  6. T1078.001 Default Accounts1

Número de CVE de esta tecnología asignadas a cada técnica de explotación o de impacto principal.