CVE-2024-41794
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could allow unauthenticated remote attackers to gain full access to a device, if they are in possession of these credentials and if the ssh service is enabled (e.g., by exploitation of CVE-2024-41793).
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 10
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.62%
- Percentil entre todas las CVEs puntuadas: 48
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1190Exploit Public-Facing Applicationinitial access85 % - Impacto principal
T1078.001Default Accountsstealth · persistence · privilege escalation · initial access90 %
Credenciales hardcodeadas accesibles remotamente sin autenticación (CWE-798, AV:N/PR:N) permiten acceso no autorizado con privilegios root. Explotación remota de red con vector CVSS crítico.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-798
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-41794",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-41794",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-04-08T13:37:36.960442Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 10,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 6,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 10,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "SENTRON 7KT PAC1260 Data Manager",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2025-04-08T09:15:20.010",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-187636.html",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could allow unauthenticated remote attackers to gain full access to a device, if they are in possession of these credentials and if the ssh service is enabled (e.g., by exploitation of CVE-2024-41793)."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SENTRON 7KT PAC1260 Data Manager (todas las versiones). Los dispositivos afectados contienen credenciales codificadas para el acceso remoto al sistema operativo del dispositivo con privilegios de root. Esto podría permitir que atacantes remotos no autenticados obtengan acceso completo a un dispositivo si poseen estas credenciales y el servicio SSH está habilitado (por ejemplo, mediante la explotación de CVE-2024-41793)."
}
],
"lastModified": "2026-06-17T07:48:14.683",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:7kt_pac1260_data_manager_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5E6C441C-751B-4D8B-967B-8237E181F21A"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:7kt_pac1260_data_manager:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "129B89C3-6730-47B7-9D07-41116E8230A0"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}