Schneider-electric
Schneider-electric Modicom Quantum Firmware: vulnerabilidades y CVE
Schneider-electric Modicom Quantum Firmware tiene 8 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 2 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE8
Últimos 12 meses0
Críticas2
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2018-7833 | Alta (7.5) | 1.4% | — | 17 dic 2018 | An Improper Check for Unusual or Exceptional Conditions vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where an unauthenticated user can send a specially… |
| CVE-2018-7812 | Alta (7.5) | 3.7% | — | 17 dic 2018 | An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses in a way that exposes… |
| CVE-2018-7804 | Media (6.1) | 0.86% | — | 17 dic 2018 | A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL… |
| CVE-2018-7831 | Alta (8.8) | 0.64% | — | 30 nov 2018 | An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a… |
| CVE-2018-7830 | Alta (7.5) | 2.4% | — | 30 nov 2018 | Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a denial of service… |
| CVE-2018-7811 | Crítica (9.8) | 3.5% | — | 30 nov 2018 | An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the change password… |
| CVE-2018-7810 | Media (6.1) | 0.90% | — | 30 nov 2018 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to… |
| CVE-2018-7809 | Crítica (9.8) | 2.5% | — | 30 nov 2018 | An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the password delete… |
Otros productos de Schneider-electric
Struxureware Data Center Expert · 49Interactive Graphical Scada System · 43Modicon M580 Firmware · 41Modicon M340 Firmware · 39Modicon M340 Bmxp342020 Firmware · 32Modicon M340 Bmxp3420302 Firmware · 28Modicon M340 Bmxp341000 Firmware · 27Ecostruxure Control Expert · 26Modicon M340 Bmxp342000 Firmware · 25Modicon Quantum Firmware · 25Modicon M340 Bmxp3420102 Firmware · 25Easergy T300 Firmware · 24