| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 1.4% | — | Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware | 17/12/2018 | 17/6/2026 | An Improper Check for Unusual or Exceptional Conditions vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where an unauthenticated user can send a specially crafted XML data via a POST request to cause the web server to become unavailable | |
| Modificada | Alta (7.5) | 3.7% | — | Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware | 17/12/2018 | 17/6/2026 | An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses in a way that exposes security-relevant information about the state of the product, such as whether a particular… | |
| Modificada | Media (6.1) | 0.86% | — | Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware | 17/12/2018 | 17/6/2026 | A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing. | |
| Modificada | Alta (8.8) | 0.64% | — | Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware | 30/11/2018 | 17/6/2026 | An Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to send a specially crafted URL to a currently authenticated web server user to execute a password change on… | |
| Modificada | Alta (7.5) | 2.4% | — | Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware | 30/11/2018 | 17/6/2026 | Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a denial of service can occur for ~1 minute by sending a specially crafted HTTP request. | |
| Modificada | Crítica (9.8) | 3.5% | — | Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware | 30/11/2018 | 17/6/2026 | An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the change password function of the web server | |
| Modificada | Media (6.1) | 0.90% | — | Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware | 30/11/2018 | 17/6/2026 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed within the user's browser, potentially… | |
| Modificada | Crítica (9.8) | 2.5% | — | Schneider-electric Modicom M340 FirmwareSchneider-electric Modicom Premium FirmwareSchneider-electric Modicom Quantum FirmwareSchneider-electric Modicom Bmxnor0200h Firmware | 30/11/2018 | 17/6/2026 | An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the password delete function of the web server. |