Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas3001▼ 62 respecto a la semana anterior
Críticas / altas1373▲ 34 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)459▼ 50 respecto a la semana anterior
17 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 0.43% | — | Schneider-electric Ecostruxure Machine Expert - HvacSchneider-electric Somachine Hvac | 30/1/2023 | 17/6/2026 | A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0) | |
| Modificada | Media (6.8) | 1.1% | — | Schneider-electric Modicon M258 FirmwareSchneider-electric SomachineSchneider-electric Somachine Motion | 11/12/2020 | 17/6/2026 | A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not… | |
| Modificada | Crítica (9.8) | 1.6% | — | Schneider-electric Ecostruxure Machine ExpertSchneider-electric Somachine BasicSchneider-electric Modicon M100 FirmwareSchneider-electric Modicon M200 Firmware+1 | 22/4/2020 | 17/6/2026 | A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the… | |
| Modificada | Alta (7.5) | 0.88% | — | Schneider-electric Ecostruxure Machine ExpertSchneider-electric SomachineSchneider-electric Somachine MotionSchneider-electric Modicon M218 Firmware+3 | 22/4/2020 | 17/6/2026 | A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. | |
| Modificada | Crítica (9.8) | 0.69% | — | Schneider-electric Ecostruxure Machine ExpertSchneider-electric SomachineSchneider-electric Somachine MotionSchneider-electric Modicon M218 Firmware+3 | 22/4/2020 | 17/6/2026 | A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers. | |
| Modificada | Alta (7.8) | 1.2% | — | Schneider-electric Somachine Hvac | 17/9/2019 | 17/6/2026 | A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product. | |
| Modificada | Media (5.3) | 1.3% | — | Schneider-electric Somachine BasicSchneider-electric Modicon M221 Firmware | 22/5/2019 | 17/6/2026 | A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause remote launch of SoMachine Basic when sending crafted ethernet message. | |
| Modificada | Media (5.5) | 0.31% | — | Schneider-electric Somachine BasicSchneider-electric Modicon M221 Firmware | 22/5/2019 | 17/6/2026 | An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting SoMachine Basic. | |
| Modificada | Alta (7.5) | 1.1% | — | Schneider-electric Somachine BasicSchneider-electric Modicon M221 Firmware | 22/5/2019 | 17/6/2026 | An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause cycle time impact when flooding the M221 ethernet interface while the Ethernet/IP adapter is activated. | |
| Modificada | Alta (8.2) | 0.66% | — | Schneider-electric Somachine Basic | 2/11/2018 | 17/6/2026 | A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device. | |
| Modificada | Alta (7.5) | 1.6% | — | Schneider-electric Somachine Basic | 3/7/2018 | 17/6/2026 | Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. The vulnerability is triggered when input passed to the xml… | |
| Modificada | Alta (8.8) | 2.4% | — | Schneider-electric Somachine | 7/6/2017 | 17/6/2026 | A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL. | |
| Modificada | Alta (7.3) | 0.39% | — | Schneider-electric Somachine Hvac | 7/6/2017 | 17/6/2026 | A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller. | |
| Modificada | Crítica (9.8) | 1.3% | — | Schneider-electric Modicon Tm221ce16r FirmwareSchneider-electric Somachine | 6/4/2017 | 17/6/2026 | Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC… | |
| Modificada | Alta (7.3) | 5.0% | — | Schneider-electric Somachine Hvac Firmware | 15/7/2016 | 17/6/2026 | An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag. | |
| Modificada | Alta (7.5) | 5.6% | — | Schneider-electric SomachineSchneider-electric SomoveSchneider-electric Somove LiteSchneider-electric Unity PRO | 1/2/2015 | 17/6/2026 | Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB… | |
| Modificada | Alta (9.3) | 22% | — | Schneider-electric ConceptSchneider-electric Modbus Serial DriverSchneider-electric Modbuscommdtm SLSchneider-electric OPC Factory Server+9 | 1/4/2014 | 16/6/2026 | Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. |