CVE-2017-7965
Estado: ModificadaAlta (7.3)—
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.39%
- Percentil entre todas las CVEs puntuadas: 31
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-119
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2017-7965",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.6,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"authentication": "NONE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 3.9,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.3,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.3
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric SE",
"product": "SoMachine HVAC Programming Software",
"versions": [
{
"status": "affected",
"version": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
]
}
],
"published": "2017-06-07T19:29:00.197",
"references": [
{
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "http://www.securityfocus.com/bid/98449",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cybersecurity@se.com"
},
{
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/98449",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de desbordamiento de búfer en el ejecutable del Software de Programación AlTracePrint.exe, en SoMachine HVAC versión v2.1.0 de Schneider Electric para el controlador Modicon M171/M172."
}
],
"lastModified": "2026-06-17T01:25:33.503",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:somachine_hvac:2.1.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "0F523B8A-A5DE-40F0-9D17-4DB519107368"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}