| Modificada | Alta (7.5) | 0.90% | — | Siemens Simatic CFU DIQ FirmwareSiemens Simatic CFU PA FirmwareSiemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-400h V6 Firmware+8 | 12/4/2022 | 17/6/2026 | The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially… | |
| Modificada | Alta (7.5) | 1.7% | — | Siemens KTK Ate530s FirmwareSiemens Sidoor Atd430w FirmwareSiemens Sidoor Ate530s Coated FirmwareSiemens Sidoor Ate531s Firmware+29 | 14/4/2020 | 17/6/2026 | A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L… | |
| Modificada | Alta (7.5) | 1.7% | — | Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-300 CPU 312 IFM FirmwareSiemens Simatic S7-300 CPU 313 FirmwareSiemens Simatic S7-300 CPU 314 Firmware+8 | 10/3/2020 | 17/6/2026 | A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94).… | |
| Modificada | Alta (7.5) | 2.1% | — | Siemens DK Standard Ethernet Controller FirmwareSiemens Ek-ertec 200 FirmwareSiemens Ek-ertec 200p FirmwareSiemens Simatic CFU PA Firmware+62 | 10/10/2019 | 17/6/2026 | Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition. | |
| Modificada | Alta (7.5) | 1.4% | — | Siemens Cp1604 FirmwareSiemens Cp1616 FirmwareSiemens DK Standard Ethernet Controller FirmwareSiemens Ek-ertec 200 Firmware+36 | 10/10/2019 | 17/6/2026 | An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. | |
| Modificada | Media (5.9) | 1.5% | — | Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-400 CPU Firmware | 17/12/2016 | 17/6/2026 | A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All… | |
| Modificada | Alta (7.5) | 3.0% | — | Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-400 CPU Firmware | 17/12/2016 | 17/6/2026 | A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All… | |
| Modificada | Alta (8.8) | 1.1% | — | Siemens Simatic S7 300 CPU FirmwareSiemens Simatic CP 443-1 FirmwareSiemens Simatic CP 343-1 FirmwareSiemens Simatic S7 400 CPU Firmware | 23/11/2016 | 17/6/2026 | A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS… | |
| Modificada | Media (5.3) | 1.9% | — | Siemens Simatic CP 343-1 FirmwareSiemens Simatic S7 300 CPU FirmwareSiemens Simatic S7 400 CPU FirmwareSiemens Simatic CP 443-1 Firmware | 23/11/2016 | 17/6/2026 | A vulnerability has been identified in SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.0.53), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variant) (All versions < V3.2.17), SIMATIC S7-300 PN/DP CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP CPU family (incl. SIPLUS… | |
| Modificada | Alta (7.5) | 35% | — | Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-300 CPU | 7/3/2015 | 17/6/2026 | Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus. |