CVE-2019-18336
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.72%
- Percentil entre todas las CVEs puntuadas: 77
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (12)
CWE
- CWE-400
- CWE-400
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-18336",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2019-18336",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-06-02T18:35:38.583256Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 7.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 6.9,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens AG",
"product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"versions": [
{
"status": "affected",
"version": "All versions < V3.X.17"
}
]
},
{
"vendor": "Siemens AG",
"product": "SIMATIC TDC CP51M1",
"versions": [
{
"status": "affected",
"version": "All versions < V1.1.8"
}
]
},
{
"vendor": "Siemens AG",
"product": "SIMATIC TDC CPU555",
"versions": [
{
"status": "affected",
"version": "All versions < V1.1.1"
}
]
},
{
"vendor": "Siemens AG",
"product": "SINUMERIK 840D sl",
"versions": [
{
"status": "affected",
"version": "All versions < V4.8.6"
}
]
},
{
"vendor": "Siemens AG",
"product": "SINUMERIK 840D sl",
"versions": [
{
"status": "affected",
"version": "All versions < V4.94"
}
]
}
]
}
],
"published": "2020-03-10T20:15:18.633",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf",
"tags": [
"Vendor Advisory"
],
"source": "productcert@siemens.com"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC S7-300 CPU family (incluyendo las variantes relacionadas a ET200 CPUs y SIPLUS) (Todas las versiones anteriores a V3.X.17), SIMATIC TDC CP51M1 (Todas las versiones anteriores a V1.1.8), SIMATIC TDC CPU555 (Todas las versiones anteriores a V1.1.1), SINUMERIK 840D sl (Todas las versiones anteriores a V4.8.6), SINUMERIK 840D sl (Todas las versiones anteriores a V4.94). Los paquetes especialmente diseñados enviados hacia el puerto 102/tcp (Profinet) pueden hacer que el dispositivo afectado entre en modo de defecto. Es requerido un reinicio para recuperar el sistema. Una explotación con éxito requiere que un atacante tenga acceso de red al puerto 102/tcp, sin autenticación. No es requerida una interacción del usuario. Al momento de la publicación del aviso no se conocía una explotación pública de esta vulnerabilidad de seguridad"
}
],
"lastModified": "2026-06-17T02:24:51.573",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C87674A8-B518-4910-B03D-FFF4D5A7B627",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "602FB384-0DB2-488C-B3CC-96E3A2882976"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7B0C6327-7BF6-4B96-82A8-D750007869EE",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "CCFCAA2B-71FE-4DB4-B8B0-F5FD1254C331"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3EF9F3FB-FBBA-42A8-9A90-FE34703274B5",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "4E6E900F-63C1-4E50-9DCD-26CE760E5275"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "8F2F0659-CD37-4AA9-B7D5-44639515533C",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "07AD63B6-B05C-4BBF-812D-379C4D8F8CC7",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8BE7963C-7AFF-495B-9F0B-28FB393443FD"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7F2A0C75-E360-4E3D-85DA-878E39054E26",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E3962681-E32E-4BD1-8C71-8768248691D4"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "488F0774-43DA-455D-905C-C514A0192260",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E8FD8E6D-0527-4215-B6F0-5824011433FB"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "F103C351-99C9-4F7D-B69A-D8A876F57504",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "644AD6A8-AEDE-4F1C-92F8-836877A81310"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BA99549B-5E95-445A-A95B-1CDA7014686B",
"versionEndExcluding": "3.3.17"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FF58C652-E74D-4B57-A7C5-08D7446863D5"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "FF920288-3AB2-4A7A-A9D7-E40A7B3FEFEA",
"versionEndExcluding": "4.8.6"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7E42B3BE-1891-44B6-8714-DA18F8B868A0",
"versionEndExcluding": "4.94"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5C936A7A-1AF9-44E4-9CEC-0694A424616B",
"versionEndExcluding": "1.1.8"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "8DA1E7C4-6352-41A4-8A94-C24DDB456572"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D87643C3-6525-4CBD-BC0C-6B4DC30C8642",
"versionEndExcluding": "1.1.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "AE6AB995-D67B-43E5-B8FF-97C38D20CB10"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "productcert@siemens.com"
}