Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2856▼ 331 respecto a la semana anterior
Críticas / altas1383▼ 38 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)292▼ 217 respecto a la semana anterior
–

8 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.5)0.90%—Siemens Simatic CFU DIQ FirmwareSiemens Simatic CFU PA FirmwareSiemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-400h V6 Firmware+812/4/202217/6/2026
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially…
ModificadaAlta (7.5)1.7%—Siemens KTK Ate530s FirmwareSiemens Sidoor Atd430w FirmwareSiemens Sidoor Ate530s Coated FirmwareSiemens Sidoor Ate531s Firmware+2914/4/202017/6/2026
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L…
ModificadaAlta (7.5)1.7%—Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-300 CPU 312 IFM FirmwareSiemens Simatic S7-300 CPU 313 FirmwareSiemens Simatic S7-300 CPU 314 Firmware+810/3/202017/6/2026
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94).…
ModificadaAlta (7.5)2.1%—Siemens DK Standard Ethernet Controller FirmwareSiemens Ek-ertec 200 FirmwareSiemens Ek-ertec 200p FirmwareSiemens Simatic CFU PA Firmware+6210/10/201917/6/2026
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
ModificadaAlta (7.5)1.4%—Siemens Cp1604 FirmwareSiemens Cp1616 FirmwareSiemens DK Standard Ethernet Controller FirmwareSiemens Ek-ertec 200 Firmware+3610/10/201917/6/2026
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
ModificadaMedia (5.9)1.5%—Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-400 CPU Firmware17/12/201617/6/2026
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All…
ModificadaAlta (7.5)3.0%—Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-400 CPU Firmware17/12/201617/6/2026
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All…
ModificadaAlta (7.5)35%💥 ExploitSiemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-300 CPU7/3/201517/6/2026
Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus.