Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas3026▼ 51 respecto a la semana anterior
Críticas / altas1412▲ 58 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)385▼ 125 respecto a la semana anterior
11 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.5) | 0.90% | — | Siemens Simatic CFU DIQ FirmwareSiemens Simatic CFU PA FirmwareSiemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-400h V6 Firmware+8 | 12/4/2022 | 17/6/2026 | The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially… | |
| Modificada | Alta (7.5) | 1.7% | — | Siemens Sinumerik 840d SL FirmwareSiemens Simatic S7-300 CPU 312 FirmwareSiemens Simatic S7-300 CPU 314 FirmwareSiemens Simatic S7-300 CPU 315-2 DP Firmware+8 | 12/11/2020 | 17/6/2026 | A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC TDC CPU555 (All versions), SINUMERIK 840D sl (All versions). Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port 102. A cold… | |
| Modificada | Media (6.5) | 0.72% | — | Siemens Simatic S7-300 CPU 312 FirmwareSiemens Simatic S7-300 CPU 314 FirmwareSiemens Simatic S7-300 CPU 315-2 DP FirmwareSiemens Simatic S7-300 CPU 315-2 PN Firmware+10 | 9/9/2020 | 17/6/2026 | A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and… | |
| Modificada | Alta (7.5) | 1.7% | — | Siemens KTK Ate530s FirmwareSiemens Sidoor Atd430w FirmwareSiemens Sidoor Ate530s Coated FirmwareSiemens Sidoor Ate531s Firmware+29 | 14/4/2020 | 17/6/2026 | A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200eco PN, AI 8xRTD/TC, M12-L… | |
| Modificada | Alta (7.5) | 1.7% | — | Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-300 CPU 312 IFM FirmwareSiemens Simatic S7-300 CPU 313 FirmwareSiemens Simatic S7-300 CPU 314 Firmware+8 | 10/3/2020 | 17/6/2026 | A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94).… | |
| Modificada | Alta (7.5) | 1.7% | — | Siemens S7-1200 CPU 1211c FirmwareSiemens S7-1200 CPU 1212c FirmwareSiemens S7-1200 CPU 1214c FirmwareSiemens S7-1200 CPU 1215c Firmware+20 | 11/2/2020 | 17/6/2026 | A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8F PN/DP… | |
| Modificada | Alta (7.5) | 2.1% | — | Siemens DK Standard Ethernet Controller FirmwareSiemens Ek-ertec 200 FirmwareSiemens Ek-ertec 200p FirmwareSiemens Simatic CFU PA Firmware+62 | 10/10/2019 | 17/6/2026 | Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition. | |
| Modificada | Alta (7.5) | 1.4% | — | Siemens Cp1604 FirmwareSiemens Cp1616 FirmwareSiemens DK Standard Ethernet Controller FirmwareSiemens Ek-ertec 200 Firmware+36 | 10/10/2019 | 17/6/2026 | An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation. | |
| Modificada | Media (5.9) | 1.5% | — | Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-400 CPU Firmware | 17/12/2016 | 17/6/2026 | A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All… | |
| Modificada | Alta (7.5) | 3.0% | — | Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-400 CPU Firmware | 17/12/2016 | 17/6/2026 | A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All… | |
| Modificada | Alta (7.5) | 35% | — | Siemens Simatic S7-300 CPU FirmwareSiemens Simatic S7-300 CPU | 7/3/2015 | 17/6/2026 | Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus. |