Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2585▼ 302 respecto a la semana anterior
Críticas / altas1355▲ 99 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 7 respecto a la semana anterior
Sin puntuar (sin CVSS)56▼ 472 respecto a la semana anterior
10 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (7.8) | 1.2% | — | Schneider-electric Proclima | 15/7/2019 | 17/6/2026 | A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs inside the software installation, to execute arbitrary code in all versions of ProClima prior to version 8.0.0. | |
| Modificada | Crítica (9.8) | 4.5% | — | Schneider-electric Proclima | 15/7/2019 | 17/6/2026 | A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0. | |
| Modificada | Crítica (9.8) | 5.0% | — | Schneider-electric Proclima | 15/7/2019 | 17/6/2026 | A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0. | |
| Modificada | Media (6.8) | 3.8% | — | Schneider-electric Proclima | 15/12/2015 | 17/6/2026 | The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different… | |
| Modificada | Media (6.8) | 5.7% | — | Schneider-electric Proclima | 15/12/2015 | 17/6/2026 | Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method,… | |
| Modificada | Alta (9) | 6.3% | — | Schneider Electric Proclima | 27/12/2014 | 17/6/2026 | Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers. | |
| Modificada | Alta (7.5) | 4.0% | — | Schneider Electric Proclima | 27/12/2014 | 17/6/2026 | Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers. | |
| Modificada | Alta (7.5) | 2.9% | — | Schneider Electric Proclima | 27/12/2014 | 17/6/2026 | Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers. | |
| Modificada | Alta (7.5) | 3.9% | — | Schneider Electric Proclima | 27/12/2014 | 17/6/2026 | Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers. | |
| Modificada | Alta (10) | 4.4% | — | Schneider-electric Proclima | 27/12/2014 | 17/6/2026 | Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers. |