« Volver al listado

CVE-2019-6823

Estado: ModificadaCrítica (9.8)—

A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2019-6823",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 10,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "ProClima",
          "product": "ProClima all versions prior to version 8.0.0",
          "versions": [
            {
              "status": "affected",
              "version": "ProClima all versions prior to version 8.0.0"
            }
          ]
        }
      ]
    }
  ],
  "published": "2019-07-15T21:15:10.663",
  "references": [
    {
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-162-01/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0."
    },
    {
      "lang": "es",
      "value": "Una CWE-94: existe una vulnerabilidad de inyección de código en ProClima (todas las versiones anteriores a la versión 8.0.0) que podría permitir que un atacante remoto no autenticado ejecute código arbitrario en el sistema objetivo en todas las versiones de ProClima anteriores a la versión 8.0.0."
    }
  ],
  "lastModified": "2026-06-17T02:39:44.650",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1C7BB1CA-CCED-4EC9-81F4-16633561E4CF",
              "versionEndExcluding": "8.0.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}