AplazadaAlta (7.5)0.63%—Codesys OPC UA ServerAI18/3/202517/6/2026
An unauthenticated remote attacker can gain access to sensitive information including authentication information when using CODESYS OPC UA Server with the non-default Basic128Rsa15 security policy.
AplazadaMedia (5.3)0.46%—Siemens Simatic Energy Manager BasicAISiemens Simatic Energy Manager PROAISiemens Simatic IPC DiagbaseAISiemens Simatic IPC DiagmonitorAI+29/7/202417/6/2026
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA…
ModificadaMedia (5.3)0.36%—Integrationobjects OPC UA Server Toolkit16/1/202417/6/2026
OPCUAServerToolkit will write a log message once an OPC UA client has successfully connected containing the client's self-defined description field.
ModificadaMedia (5.5)0.21%—Ecostruxure OPC UA Server Expert12/7/202317/6/2026
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause loss of confidentiality when replacing a project file on the local filesystem and after manual restart of the server.
ModificadaAlta (7.5)2.6%—Opcfoundation Local Discover ServerSiemens Simatic Process Historian OPC UA Server FirmwareSiemens Simatic NET PCSiemens Simatic Wincc+327/8/202117/6/2026
In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer.
ModificadaMedia (5.3)0.95%—Beckhoff IPC Diagnostics UA ServerBeckhoff Tf6100Beckhoff Twincat OPC UA Server13/5/202117/6/2026
TwinCAT OPC UA Server in versions up to 2.3.0.12 and IPC Diagnostics UA Server in versions up to 3.1.0.1 from Beckhoff Automation GmbH & Co. KG are vulnerable to denial of service attacks. The attacker needs to send several specifically crafted requests to the running OPC UA server. After some of these requests the…
ModificadaMedia (5.9)64%—OpensslDebian LinuxFreebsdNetapp Active IQ Unified Manager+10225/3/202117/6/2026
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer…
ModificadaAlta (7.5)1.6%—Siemens Simatic Cp443-1 OPC UA FirmwareSiemens Simatic ET 200 Open Controller CPU 1515sp PC2 FirmwareSiemens Simatic IPC Diagmonitor FirmwareSiemens Simatic NET PC Software Firmware+2317/4/201917/6/2026
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl.…