« Volver al listado

CVE-2023-37200

Estado: ModificadaMedia (5.5)—

A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause loss of confidentiality when replacing a project file on the local filesystem and after manual restart of the server.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-37200",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-37200",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-07T14:06:52.880283Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "EcoStruxure OPC UA Server Expert",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to SV2.01 SP2"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-07-12T08:15:10.203",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-02.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-02.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-611"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nA CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that\ncould cause loss of confidentiality when replacing a project file on the local filesystem and after\nmanual restart of the server. \n\n\n"
    }
  ],
  "lastModified": "2026-06-17T06:07:42.707",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:se:ecostruxure_opc_ua_server_expert:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "89F38F9E-3BD3-4964-A940-89A54C2445BC",
              "versionEndExcluding": "2.01"
            },
            {
              "criteria": "cpe:2.3:a:se:ecostruxure_opc_ua_server_expert:2.01:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "57255D20-34C7-45D8-9139-B61444E7AAD4"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}