CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaMedia (5.5)0.17%—Schneider-electric OPC Factory Server16/5/202317/6/2026
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user.
ModificadaAlta (7.3)0.46%—Schneider-electric OPC Factory Server25/3/201917/6/2026
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20…
ModificadaAlta (7.8)2.5%—Schneider-electric OPC Factory Server TlxcdlfofsSchneider-electric OPC Factory Server TlxcdltofsSchneider-electric OPC Factory Server TlxcdluofsSchneider-electric OPC Factory Server Tlxcdstofs+14/4/201417/6/2026
Multiple buffer overflows in the OPC Automation 2.0 Server Object ActiveX control in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 3.5 and earlier, TLXCDSTOFS33 3.5 and earlier, TLXCDLUOFS33 3.5 and earlier, TLXCDLTOFS33 3.5 and earlier, and TLXCDLFOFS33 3.5 and earlier allow remote attackers to cause a…
ModificadaAlta (9.3)22%—Schneider-electric ConceptSchneider-electric Modbus Serial DriverSchneider-electric Modbuscommdtm SLSchneider-electric OPC Factory Server+91/4/201416/6/2026
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
ModificadaMedia (6.9)0.47%—Schneider-electric OFS Test Client Tlxcdlfofs33Schneider-electric OFS Test Client Tlxcdltofs33Schneider-electric OFS Test Client Tlxcdluofs33Schneider-electric OFS Test Client Tlxcdstofs33+228/2/201417/6/2026
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
ModificadaAlta (7.2)1.3%—Schneider-electric Monitor PROSchneider-electric OPC Factory ServerSchneider-electric PL7 PROSchneider-electric Telemecanique Driver Pack+24/11/201116/6/2026
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers,…