« Volver al listado

CVE-2023-2161

Estado: ModificadaMedia (5.5)—

A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2023-2161",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-2161",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-01-22T21:45:03.652513Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.3
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.5,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "OPC Factory Server (OFS)",
          "versions": [
            {
              "status": "affected",
              "version": "Versions prior to V3.63SP2"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2023-05-16T05:15:09.357",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-129-01.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-129-01.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-611"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-611"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nA CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that\ncould cause unauthorized read access to the file system when a malicious configuration file is\nloaded on to the software by a local user. "
    }
  ],
  "lastModified": "2026-06-17T05:51:53.447",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:opc_factory_server:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8157EA01-7338-4192-B5B0-0AAE18F856E9",
              "versionEndExcluding": "3.63"
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:opc_factory_server:3.63:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E308BCBF-DE73-4CF1-85FD-CB216CEF9410"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],