CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaCrítica (9.8)58%—Mitsubishielectric Smartrtu FirmwareInea Me-rtu Firmware28/10/201917/6/2026
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's system shell.…
ModificadaCrítica (9.8)2.3%—Mitsubishielectric Smartrtu FirmwareInea Me-rtu Firmware28/10/201917/6/2026
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are…
ModificadaCrítica (9.8)1.9%—Mitsubishielectric Smartrtu FirmwareInea Me-rtu Firmware28/10/201917/6/2026
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. An…
ModificadaMedia (5.4)44%—Mitsubishielectric Smartrtu FirmwareInea Me-rtu Firmware28/10/201917/6/2026
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is…
ModificadaAlta (7.5)42%—Mitsubishielectric Smartrtu FirmwareInea Me-rtu Firmware28/10/201917/6/2026
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other…
ModificadaCrítica (9.8)2.1%—Mitsubishielectric Smartrtu FirmwareInea Me-rtu Firmware28/10/201917/6/2026
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In…
ModificadaMedia (6.5)1.3%—Mitsubishielectric Smartrtu FirmwareInea Me-rtu Firmware28/10/201917/6/2026
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other…