CVE-2019-14927
Estado: ModificadaAlta (7.5)—
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 42%
- Percentil entre todas las CVEs puntuadas: 99
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-306, CWE-425
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2019-14927",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2019-10-28T13:15:10.773",
"references": [
{
"url": "https://www.mogozobo.com/",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.mogozobo.com/?p=3593",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://www.mogozobo.com/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.mogozobo.com/?p=3593",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-306"
},
{
"lang": "en",
"value": "CWE-425"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data)."
},
{
"lang": "es",
"value": "Se descubrió un problema en los dispositivos Mitsubishi Electric ME-RTU versiones hasta la versión 2.02 y los dispositivos INEA ME-RTU versiones hasta la versión 3.0. Una vulnerabilidad de descarga de configuración remota no autenticada permite a un atacante descargar el archivo de configuración de smartRTU (que contiene datos como nombres de usuario, contraseñas y otros datos confidenciales de RTU)."
}
],
"lastModified": "2026-06-17T02:19:20.027",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "62D6CAA7-11E1-4DF2-A9BD-EC71AE7CD166",
"versionEndIncluding": "2.02"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1EF90DA0-55C7-4765-9DEE-80145752961D"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DDC6C049-B15B-4FC2-9DDF-915381E6D114",
"versionEndIncluding": "3.0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "FD7F8299-4A9C-4B93-A35A-68C6D43855CC"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}