Vulnerabilidades nuevas2817▼ 183 respecto a la semana anterior
Críticas / altas1372▲ 48 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)247▼ 271 respecto a la semana anterior
–

10 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaAlta (7.8)0.34%—Rockwellautomation Isagraf Workbench25/8/202217/6/2026
Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Deserialization of Untrusted Data vulnerability. ISaGRAF Workbench does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user…
ModificadaAlta (7.8)0.29%—Rockwellautomation Isagraf Workbench25/8/202217/6/2026
Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Path Traversal vulnerability. Crafted malicious files can allow an attacker to traverse the file system when opened by ISaGRAF Workbench. If successfully exploited, an attacker could overwrite existing files and create…
ModificadaAlta (7.8)2.6%—Rockwellautomation Isagraf Workbench25/8/202217/6/2026
Rockwell Automation ISaGRAF Workbench software versions 6.0 through 6.6.9 are affected by a Path Traversal vulnerability. A crafted malicious .7z exchange file may allow an attacker to gain the privileges of the ISaGRAF Workbench software when opened. If the software is running at the SYSTEM level, then the attacker…
ModificadaAlta (7.8)11%—Rockwellautomation Connected Component WorkbenchRockwellautomation Isagraf WorkbenchRockwellautomation Safety Instrumented Systems Workstation17/5/202217/6/2026
Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local…
ModificadaMedia (5.5)2.2%—Rockwellautomation Connected Components WorkbenchRockwellautomation IsagrafRockwellautomation Safety Instrumented Systems Workstation1/4/202217/6/2026
When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality.
ModificadaMedia (5.5)0.44%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user…
ModificadaMedia (6.7)0.45%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
ModificadaMedia (6.5)1.2%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or…
ModificadaAlta (8.8)1.7%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated…
ModificadaCrítica (9.8)6.4%—Schneider-electric Easergy T300 FirmwareSchneider-electric Easergy C5 FirmwareSchneider-electric Micom C264 FirmwareSchneider-electric Pacis GTW Firmware+1318/3/202217/6/2026
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an…