CVE-2022-1018
Estado: ModificadaMedia (5.5)—
When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
- Puntuación base: 5.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.15%
- Percentil entre todas las CVEs puntuadas: 82
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-611
- CWE-611
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-1018",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-1018",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-04-16T15:54:59.168246Z"
}
}
],
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.5,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 1.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.5,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "Connected Component Workbench",
"versions": [
{
"status": "affected",
"version": "All",
"lessThan": "12",
"versionType": "custom"
}
]
},
{
"vendor": "Rockwell Automation",
"product": "ISaGRAF",
"versions": [
{
"status": "affected",
"version": "All",
"lessThan": "6.6.9",
"versionType": "custom"
}
]
},
{
"vendor": "Rockwell Automation",
"product": "Safety Instrumented Systems Workstation",
"versions": [
{
"status": "affected",
"version": "All",
"lessThan": "1.1",
"versionType": "custom"
}
]
}
]
}
],
"published": "2022-04-01T23:15:12.177",
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-088-01",
"tags": [
"Mitigation",
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-611"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-611"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality."
},
{
"lang": "es",
"value": "Cuando es abierto un archivo de solución malicioso proporcionado por un atacante, la aplicación sufre una vulnerabilidad de tipo XML external entity debido a una llamada no segura dentro de un archivo de biblioteca de enlace dinámico. Un atacante podría aprovechar esto para pasar datos de archivos locales a un servidor web remoto, conllevando a una pérdida de confidencialidad"
}
],
"lastModified": "2026-06-17T04:21:39.187",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:connected_components_workbench:*:*:*:*:-:*:*:*",
"vulnerable": true,
"matchCriteriaId": "06DE97E4-74B3-4CC2-99C4-7EB0E38D5F34",
"versionEndIncluding": "12.0"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:isagraf:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6B871240-C4D4-478D-9A6A-378A082B5365",
"versionEndIncluding": "6.6.9"
},
{
"criteria": "cpe:2.3:o:rockwellautomation:safety_instrumented_systems_workstation:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C576D1B7-D890-4172-9500-E8FFF3366E4B",
"versionEndIncluding": "1.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}