Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2847▼ 151 respecto a la semana anterior
Críticas / altas1373▲ 54 respecto a la semana anterior
Nueva explotación activa (KEV)5▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)267▼ 257 respecto a la semana anterior
9 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Media (4.8) | 0.40% | — | Schneider-electric Ion8650 FirmwareSchneider-electric Ion8800 Firmware | 15/11/2023 | 17/6/2026 | A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability exists that could cause compromise of a user’s browser when an attacker with admin privileges has modified system values. | |
| Modificada | Media (4.9) | 0.31% | — | Schneider-electric Ion8650 FirmwareSchneider-electric Ion8800 Firmware | 15/11/2023 | 17/6/2026 | A CWE-494 Download of Code Without Integrity Check vulnerability exists that could allow modified firmware to be uploaded when an authorized admin user begins a firmware update procedure which could result in full control over the device. | |
| Modificada | Crítica (9.8) | 0.38% | — | Schneider-electric Powerlogic Ion9000 FirmwareSchneider-electric Powerlogic Ion7400 FirmwareSchneider-electric Powerlogic Pm8000 FirmwareSchneider-electric Powerlogic Ion8650 Firmware+1 | 22/5/2023 | 17/6/2026 | A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or modification of data if an attacker is able to intercept network traffic. | |
| Modificada | Alta (7.5) | 1.2% | — | Schneider-electric Powerlogic Ion8650 FirmwareSchneider-electric Powerlogic Ion8800 FirmwareSchneider-electric Powerlogic Ion7550 FirmwareSchneider-electric Powerlogic Ion7650 Firmware+7 | 11/3/2021 | 17/6/2026 | A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot. | |
| Modificada | Alta (7.5) | 0.60% | — | Schneider-electric Powerlogic Ion7400 FirmwareSchneider-electric Powerlogic Ion7650 FirmwareSchneider-electric Powerlogic Ion8600 FirmwareSchneider-electric Powerlogic Ion8650 Firmware+6 | 19/2/2021 | 17/6/2026 | A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic… | |
| Modificada | Alta (7.5) | 0.59% | — | Schneider-electric Powerlogic Ion7400 FirmwareSchneider-electric Powerlogic Ion7650 FirmwareSchneider-electric Powerlogic Ion7700 FirmwareSchneider-electric Powerlogic Ion7300 Firmware+8 | 19/2/2021 | 17/6/2026 | A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet… | |
| Modificada | Media (4.5) | 0.34% | — | Schneider-electric Powerlogic Ion7400 FirmwareSchneider-electric Powerlogic Ion7650 FirmwareSchneider-electric Powerlogic Ion8600 FirmwareSchneider-electric Powerlogic Ion8650 Firmware+6 | 19/2/2021 | 17/6/2026 | A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface. | |
| Modificada | Crítica (9.8) | 2.5% | — | Schneider-electric Ion5000Schneider-electric Ion7300Schneider-electric Ion7500Schneider-electric Ion7600+2 | 13/2/2017 | 17/6/2026 | An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes. | |
| Modificada | Alta (8.8) | 2.0% | — | Schneider-electric Ion5000Schneider-electric Ion7300Schneider-electric Ion7500Schneider-electric Ion7600+2 | 13/2/2017 | 17/6/2026 | An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized… |