CVE-2023-5985
Estado: ModificadaMedia (4.8)—
A CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability exists that could cause compromise of a user’s browser when an attacker with admin privileges has modified system values.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
- Puntuación base: 4.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.40%
- Percentil entre todas las CVEs puntuadas: 32
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-5985",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-5985",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-08-29T15:18:22.109304Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 1.7
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 1.7
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "ION8650",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "ION8800 ",
"versions": [
{
"status": "affected",
"version": "All versions"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2023-11-15T04:15:19.290",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-01.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-318-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-318-01.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "\n\n\nA CWE-79 Improper Neutralization of Input During Web Page Generation vulnerability\nexists that could cause compromise of a user’s browser when an attacker with admin privileges\nhas modified system values.\n\n\n\n"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE-79: Neutralización Inadecuada de la Entrada Durante la Generación de Páginas Web que podría comprometer el navegador de un usuario cuando un atacante con privilegios de administrador ha modificado los valores del sistema."
}
],
"lastModified": "2026-06-17T06:49:48.140",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:ion8650_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6F157E99-370C-46CD-BB4F-88BC5B55E8B0"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:ion8650:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "1DA97CA0-DDE0-4418-9D72-7D463C003693"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:ion8800_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1936E11C-833A-4E02-A0F9-D53E12FB88D5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:ion8800:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "B3449157-3715-4D89-A3BD-49EE47160B25"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}