Vulnerabilidades

Resumen — últimos 7 días

Vulnerabilidades nuevas2684▼ 80 respecto a la semana anterior
Críticas / altas1442▲ 302 respecto a la semana anterior
Nueva explotación activa (KEV)7▼ 3 respecto a la semana anterior
Sin puntuar (sin CVSS)64▼ 462 respecto a la semana anterior
–

31 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
AnalizadaAlta (7.7)0.23%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process Expert14/2/202417/6/2026
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert.
AnalizadaAlta (8.1)0.32%—Schneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp341000h FirmwareSchneider-electric Modicon M340 Bmxp342000 FirmwareSchneider-electric Modicon M340 Bmxp342010 Firmware+4214/2/202417/6/2026
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack.
AnalizadaAlta (7.1)0.15%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process Expert14/2/202417/6/2026
CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering workstation.
ModificadaAlta (8.8)0.84%—Schneider-electric Ecostruxure Control Expert18/4/202317/6/2026
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above)
ModificadaMedia (5.5)0.15%—Schneider-electric Ecostruxure Control Expert18/4/202317/6/2026
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)
ModificadaCrítica (9.8)1.5%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+3331/1/202317/6/2026
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU…
ModificadaCrítica (9.8)1.2%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+5130/1/202317/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions),…
ModificadaMedia (5.5)0.20%—Schneider-electric Ecostruxure Control Expert13/9/202217/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior).
ModificadaCrítica (9.8)0.77%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+3212/9/202217/6/2026
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control…
ModificadaCrítica (9.8)2.4%—ATT XmillSchneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect14/4/202217/6/2026
A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or…
ModificadaAlta (7.8)26%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect13/4/202217/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software.…
ModificadaMedia (5.9)0.86%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process Expert9/3/202217/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process…
ModificadaMedia (5.9)0.64%—Schneider-electric Ecostruxure Control Expert9/3/202217/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product:…
ModificadaAlta (7.5)0.94%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-476: NULL Pointer Dereference vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers…
ModificadaMedia (6.5)0.84%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all…
ModificadaMedia (6.5)0.84%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions), Modicon M340 CPU (part numbers BMXP34*, all…
ModificadaMedia (6.5)0.84%—Schneider-electric Modicon M340 Bmxp341000Schneider-electric Modicon M340 Bmxp342010Schneider-electric Modicon M340 Bmxp342020Schneider-electric Modicon M340 Bmxp342030+452/9/202117/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all…
ModificadaMedia (5.5)0.11%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect14/7/202117/6/2026
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could…
ModificadaMedia (5.5)0.24%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect14/7/202117/6/2026
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could…
ModificadaAlta (7.1)0.22%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect14/7/202117/6/2026
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could…
ModificadaCrítica (9.1)1.0%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric RemoteconnectSchneider-electric Modicon M580 Bmep581020 Firmware+2814/7/202117/6/2026
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70…
ModificadaAlta (7.1)0.22%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Remoteconnect14/7/202117/6/2026
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could…
ModificadaAlta (8.6)1.4%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Unity PRO11/12/202017/6/2026
A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software.
ModificadaAlta (7.5)1.9%—Schneider-electric Ecostruxure Control Expert19/11/202017/6/2026
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request…
ModificadaAlta (7.5)1.3%—Schneider-electric Ecostruxure Control Expert19/11/202017/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.