CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaCrítica (9.8)1.5%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+3331/1/202317/6/2026
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU…
ModificadaAlta (8.3)0.14%—Schneider-electric Ecostruxure Cybersecurity Admin Expert30/1/202317/6/2026
A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the…
ModificadaAlta (8.1)0.31%—Schneider-electric Ecostruxure Cybersecurity Admin Expert30/1/202317/6/2026
A CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause legitimate users to be locked out of devices or facilitate backdoor account creation by spoofing a device on the local network. Affected Products: EcoStruxure™ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2)
ModificadaCrítica (9.8)1.3%—Schneider-electric Interactive Graphical Scada System30/1/202317/6/2026
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to…
ModificadaCrítica (9.1)0.47%—Schneider-electric Interactive Graphical Scada System30/1/202317/6/2026
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affected Products: IGSS Data Server -…
ModificadaCrítica (9.8)1.3%—Schneider-electric Interactive Graphical Scada System30/1/202317/6/2026
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to…
ModificadaCrítica (9.8)1.3%—Schneider-electric Interactive Graphical Scada System30/1/202317/6/2026
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to…
ModificadaCrítica (9.8)1.3%—Schneider-electric Interactive Graphical Scada System30/1/202317/6/2026
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
ModificadaCrítica (9.8)1.3%—Schneider-electric Interactive Graphical Scada System30/1/202317/6/2026
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to…
ModificadaCrítica (9.8)1.3%—Schneider-electric Interactive Graphical Scada System30/1/202317/6/2026
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to…
ModificadaCrítica (9.8)1.1%—Schneider-electric Interactive Graphical Scada System30/1/202317/6/2026
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe…
ModificadaAlta (8.8)0.54%—Schneider-electric Data Center Expert30/1/202317/6/2026
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)
ModificadaCrítica (9.8)0.54%—Schneider-electric Data Center Expert30/1/202317/6/2026
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
ModificadaCrítica (9.8)0.48%—Schneider-electric Data Center Expert30/1/202317/6/2026
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
ModificadaCrítica (9.8)0.54%—Schneider-electric Data Center Expert30/1/202317/6/2026
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
ModificadaMedia (6.5)0.43%—Schneider-electric Conext Combox Firmware30/1/202317/6/2026
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses.…
ModificadaMedia (6.5)0.25%—Schneider-electric Conext Combox Firmware30/1/202317/6/2026
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system’s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext™ ComBox (All Versions)
ModificadaCrítica (9.8)0.64%—Schneider-electric Conext Combox Firmware30/1/202317/6/2026
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
ModificadaCrítica (9.8)0.79%—Schneider-electric 5500ac2 FirmwareSchneider-electric 5500nac FirmwareSchneider-electric 5500nac2 FirmwareSchneider-electric 5500shac Firmware+230/1/202317/6/2026
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to…
ModificadaCrítica (9.8)0.69%—Schneider-electric 5500ac2 FirmwareSchneider-electric 5500nac FirmwareSchneider-electric 5500nac2 FirmwareSchneider-electric 5500shac Firmware+230/1/202317/6/2026
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC…
ModificadaAlta (7.8)0.26%—Schneider-electric Canbrass30/1/202317/6/2026
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1)
ModificadaAlta (7.5)0.27%—Schneider-electric Ecostruxure Power Commission30/1/202317/6/2026
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
ModificadaCrítica (9.8)0.78%—Schneider-electric Ecostruxure Power Commission30/1/202317/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal attacks. Affected Products: EcoStruxure…
ModificadaCrítica (9.8)0.78%—Schneider-electric Ecostruxure Power Commission30/1/202317/6/2026
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power…
ModificadaCrítica (9.8)1.2%—Schneider-electric Ecostruxure Control ExpertSchneider-electric Ecostruxure Process ExpertSchneider-electric Modicon M340 Bmxp341000 FirmwareSchneider-electric Modicon M340 Bmxp342000 Firmware+5130/1/202317/6/2026
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Affected Products: EcoStruxure Control Expert (All Versions),…