CVE-2022-0223
Estado: ModificadaCrítica (9.8)—
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.78%
- Percentil entre todas las CVEs puntuadas: 54
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-22
Referencias
- https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf
- https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2022-0223",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-0223",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-02-05T19:50:51.006673Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "EcoStruxure Power Commission",
"versions": [
{
"status": "affected",
"version": "All",
"lessThan": "V2.22",
"versionType": "custom"
}
]
}
]
}
],
"published": "2023-01-30T23:15:09.427",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE-22: limitación inadecuada de un nombre de ruta a un directorio restringido (\"Path Traversal\") que podría permitir a un atacante crear o sobrescribir archivos críticos que se utilizan para ejecutar código, como programas o librerías, y provocar la ejecución de código no autenticado. Productos afectados: EcoStruxure Power Commission (versiones anteriores a la V2.22)"
}
],
"lastModified": "2026-06-17T04:20:10.967",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_commission:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E59BB009-9A61-46F7-BC46-44B4EC678EE4",
"versionEndExcluding": "2.22"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cybersecurity@se.com"
}