Resumen — últimos 7 días

Vulnerabilidades nuevas2733▼ 589 respecto a la semana anterior
Críticas / altas1313▼ 190 respecto a la semana anterior
Nueva explotación activa (KEV)4▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)294▼ 216 respecto a la semana anterior
–

159 resultados, ordenados por fecha de publicación (más recientes primero)

CVEEstadoSeveridadEPSS Explotación activaTecnologías afectadasPublicada ▼Modificada Descripción
ModificadaCrítica (9.8)0.89%—Tendacn Ac10u Firmware26/1/202417/6/2026
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formQuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public…
ModificadaCrítica (9.8)0.98%—Tenda Ac10 Firmware29/11/202317/6/2026
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic.
ModificadaCrítica (9.8)0.98%—Tenda Ac10 Firmware29/11/202317/6/2026
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time.
ModificadaCrítica (9.8)0.98%—Tenda Ac10 Firmware29/11/202317/6/2026
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
ModificadaCrítica (9.8)0.98%—Tenda Ac10 Firmware29/11/202317/6/2026
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.
ModificadaCrítica (9.8)0.98%—Tenda Ac10 Firmware29/11/202317/6/2026
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
ModificadaCrítica (9.8)0.98%—Tenda Ac10 Firmware29/11/202317/6/2026
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098.
ModificadaCrítica (9.8)1.1%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
ModificadaCrítica (9.8)1.1%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
ModificadaCrítica (9.8)1.1%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the formSetClientState function.
ModificadaCrítica (9.8)1.1%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
ModificadaCrítica (9.8)1.1%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the mac parameter in the GetParentControlInfo function.
ModificadaCrítica (9.8)16%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the domain parameter in the add_white_node function.
ModificadaCrítica (9.8)1.1%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function.
ModificadaCrítica (9.8)1.1%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
ModificadaCrítica (9.8)0.79%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the schedEndTime parameter in the setSchedWifi function.
ModificadaCrítica (9.8)1.1%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain multiple stack overflows in the formSetMacFilterCfg function via the macFilterType and deviceList parameters.
ModificadaCrítica (9.8)1.1%—Tendacn Ac10u Firmware27/9/202317/6/2026
Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the list parameter in the fromSetIpMacBind function.
ModificadaCrítica (9.8)1.2%—Tenda Ac10 Firmware18/9/202317/6/2026
Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function.
ModificadaCrítica (9.8)0.93%—Tenda Ac10v4 Firmware24/8/202317/6/2026
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
ModificadaCrítica (9.8)1.2%—Tenda Ac10v4 Firmware24/8/202317/6/2026
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
ModificadaCrítica (9.8)1.3%—Tenda Ac10v4 Firmware24/8/202317/6/2026
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
ModificadaCrítica (9.8)0.84%—Tenda Ac10 FirmwareTenda Ac1206 FirmwareTenda AC8 FirmwareTenda AC6 Firmware+37/8/202317/6/2026
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
ModificadaCrítica (9.8)0.85%—Tenda Ac10 FirmwareTenda Ac1206 FirmwareTenda AC6 FirmwareTenda AC7 Firmware+57/8/202317/6/2026
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
ModificadaCrítica (9.8)0.85%—Tenda Ac1206 FirmwareTenda AC5 FirmwareTenda AC9 FirmwareTenda AC8 Firmware+17/8/202317/6/2026
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.