CVE-2024-0922
Estado: ModificadaCrítica (9.8)—
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formQuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 9.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.89%
- Percentil entre todas las CVEs puntuadas: 58
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-121
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-0922",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-0922",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-06-11T15:39:24.780721Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 5.8,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
"authentication": "MULTIPLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.4,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.7,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 1.2
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 9.8,
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Tenda",
"product": "AC10U",
"versions": [
{
"status": "affected",
"version": "15.03.06.49_multi_TDE01"
}
]
}
]
}
],
"published": "2024-01-26T14:15:50.527",
"references": [
{
"url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formQuickIndex.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.252127",
"tags": [
"Permissions Required",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.252127",
"tags": [
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formQuickIndex.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?ctiid.252127",
"tags": [
"Permissions Required",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.252127",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formQuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad fue encontrada en Tenda AC10U 15.03.06.49_multi_TDE01 y clasificada como crítica. La función formSetDeviceName es afectada por esta vulnerabilidad. La manipulación del argumento devName provoca un desbordamiento de búfer en la región stack de la memoria. El ataque puede lanzarse de forma remota. La explotación ha sido divulgada al público y puede utilizarse. El identificador de esta vulnerabilidad es VDB-252128. NOTA: Se contactó primeramente con proveedor sobre esta divulgación, pero no respondió de ninguna manera."
}
],
"lastModified": "2026-06-17T06:54:34.420",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D1C36BB3-509E-4120-B2EC-F4D061A71F2A"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "BFF286BB-A1D3-4E51-AB31-B5A531A8B440"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}