Vulnerabilidades
Resumen — últimos 7 días
Vulnerabilidades nuevas2678▼ 660 respecto a la semana anterior
Críticas / altas1266▼ 293 respecto a la semana anterior
Nueva explotación activa (KEV)3▼ 5 respecto a la semana anterior
Sin puntuar (sin CVSS)250▼ 252 respecto a la semana anterior
787 resultados, ordenados por fecha de publicación (más recientes primero)
| CVE | Estado | Severidad | EPSS | Explotación activa | Tecnologías afectadas | Publicada ▼ | Modificada | Descripción |
|---|---|---|---|---|---|---|---|---|
| Modificada | Alta (8.8) | 1.7% | — | Schneider-electric Bmxnor0200h Firmware | 17/9/2019 | 17/6/2026 | CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol. | |
| Modificada | Alta (7.5) | 1.8% | — | Schneider-electric Modicon M580 FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum Firmware | 17/9/2019 | 17/6/2026 | A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller. | |
| Modificada | Crítica (9.8) | 1.0% | — | Schneider-electric Ap9630 FirmwareSchneider-electric Smart-ups SRT 5kva FirmwareSchneider-electric Ap9631 FirmwareSchneider-electric Ap9635 Firmware | 17/9/2019 | 17/6/2026 | A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled. | |
| Modificada | Alta (7.8) | 1.3% | — | Schneider-electric Interactive Graphical Scada System | 15/7/2019 | 17/6/2026 | A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated. | |
| Modificada | Alta (7.8) | 1.2% | — | Schneider-electric Proclima | 15/7/2019 | 17/6/2026 | A CWE-427: Uncontrolled Search Path Element vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow a malicious DLL file, with the same name of any resident DLLs inside the software installation, to execute arbitrary code in all versions of ProClima prior to version 8.0.0. | |
| Modificada | Crítica (9.8) | 4.5% | — | Schneider-electric Proclima | 15/7/2019 | 17/6/2026 | A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0. | |
| Modificada | Crítica (9.8) | 5.0% | — | Schneider-electric Proclima | 15/7/2019 | 17/6/2026 | A CWE-94: Code Injection vulnerability exists in ProClima (all versions prior to version 8.0.0) which could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0. | |
| Modificada | Alta (7.8) | 3.7% | — | Schneider-electric Zelio Soft 2 | 15/7/2019 | 17/6/2026 | A Use After Free: CWE-416 vulnerability exists in Zelio Soft 2, V5.2 and earlier, which could cause remote code execution when opening a specially crafted Zelio Soft 2 project file. | |
| Modificada | Alta (7.5) | 1.1% | — | Schneider-electric Bmenoc0301 FirmwareSchneider-electric Modicon M580 Bmep584040 FirmwareSchneider-electric Modicon M580 Bmep586040 FirmwareSchneider-electric Bmeh586040 Firmware+9 | 15/7/2019 | 17/6/2026 | A CWE-119 Buffer Errors vulnerability exists in Modicon M580 CPU - BMEP582040, all versions before V2.90, and Modicon Ethernet Module BMENOC0301, all versions before V2.16, which could cause denial of service on the FTP service of the controller or the Ethernet BMENOC module when it receives a FTP CWD command with a… | |
| Modificada | Alta (7.8) | 0.38% | — | Schneider-electric CitectscadaSchneider-electric Scada Expert Vijeo Citect | 31/5/2019 | 17/6/2026 | In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials. | |
| Modificada | Crítica (9.8) | 8.2% | — | Schneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware | 22/5/2019 | 17/6/2026 | A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus. | |
| Modificada | Alta (7.5) | 2.2% | — | Schneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware | 22/5/2019 | 17/6/2026 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. | |
| Modificada | Alta (7.5) | 2.3% | — | Schneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware | 22/5/2019 | 17/6/2026 | A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus. | |
| Modificada | Alta (7.5) | 1.6% | — | Schneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware | 22/5/2019 | 17/6/2026 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus. | |
| Modificada | Alta (7.5) | 1.6% | — | Schneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware | 22/5/2019 | 17/6/2026 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus. | |
| Modificada | Alta (7.5) | 2.6% | — | Schneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware | 22/5/2019 | 17/6/2026 | A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus | |
| Modificada | Alta (7.5) | 2.3% | 💥 PoC | Schneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware | 22/5/2019 | 17/6/2026 | A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus. | |
| Modificada | Alta (7.5) | 1.8% | — | Schneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware | 22/5/2019 | 17/6/2026 | A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus | |
| Modificada | Alta (7.5) | 3.3% | 💥 PoC | Schneider-electric Modicon Premium FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 Firmware | 22/5/2019 | 17/6/2026 | A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus. | |
| Modificada | Media (5.9) | 1.1% | — | Schneider-electric Triconex Tristation Emulator | 22/5/2019 | 17/6/2026 | A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running… | |
| Modificada | Media (6.5) | 1.9% | — | Schneider-electric Modicon M580 FirmwareSchneider-electric Modicon M340 FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon Premium Firmware | 22/5/2019 | 17/6/2026 | CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum. | |
| Modificada | Alta (8.2) | 1.3% | — | Schneider-electric Modicon M100 FirmwareSchneider-electric Modicon M200 FirmwareSchneider-electric Modicon M221 FirmwareSchneider-electric ATV IMC Drive Controller Firmware+8 | 22/5/2019 | 17/6/2026 | A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller,… | |
| Modificada | Alta (7.5) | 1.1% | — | Schneider-electric Modicon M340 FirmwareSchneider-electric Modicon M580 FirmwareSchneider-electric Modicon Quantum FirmwareSchneider-electric Modicon Premium Firmware | 22/5/2019 | 17/6/2026 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the products: Modicon M340 - firmware versions prior to V3.01, Modicon M580 - firmware versions prior to V2.80, All firmware… | |
| Modificada | Crítica (9.1) | 1.5% | — | Schneider-electric Modicon Quantum Firmware | 22/5/2019 | 17/6/2026 | In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol. | |
| Modificada | Crítica (9.1) | 1.4% | — | Schneider-electric Modicon Quantum Firmware | 22/5/2019 | 17/6/2026 | In Modicon Quantum all firmware versions, CWE-264: Permissions, Privileges, and Access Control vulnerabilities could cause a denial of service or unauthorized modifications of the PLC configuration when using Ethernet/IP protocol. |